Permit: T15CM05706
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
4211 S SANTA RITA AV
Address NEW:
4211 S SANTA RITA AV
Apply Date:
08/17/2015
Applicant:
SHELL, STEVEN COLT
Description:
TI: REMODEL
Architects:
- SHELL, STEVEN COLT
Contractors:
- CHESTNUT BUILDING & DESIGN INC
Permit Reviews
Permit Number - T15CM05706
Permit Status: C of o
Permit Description: TI: REMODEL
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/17/2015 | COMMERCIAL - TI | 09/25/2015 | COMPLETED |
| 09/29/2015 | REVISION - - 1ST | 10/06/2015 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T15CM05706
Permit Status: C of o
Permit Description: TI: REMODEL
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/17/2015 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T15CM05706
Permit Description: TI: REMODEL
Total Completed Inspections - 28
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/08/2015 | PLUMBING - ROUGH, SOIL | MPUGH1 | Approved | IVRS - Inspection :* |
| 10/19/2015 | ELECTRIC - INTERMEDIATE | MRAMBER | Approved | 1. UNDERGROUND AT COFERENCE ROOM OK TO COVER |
| 10/22/2015 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
| 10/22/2015 | SHEET ROCK NAILING | MRAMBER | Approved | IVRS - Inspection :* |
| 10/27/2015 | PLUMBING - INTERMEDIATE | MPUGH1 | Approved | IVRS - Inspection :* |
| 11/02/2015 | FRAMING | RCAMACHO | Approved | IVRS - Inspection :* |
| 11/24/2015 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 11/24/2015 | PLUMBING - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 11/24/2015 | ELECTRIC - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 11/24/2015 | BUILDING ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 12/10/2015 | RIGHT OF WAY - FINAL | JCASTRO | Approved | |
| 12/11/2015 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 12/11/2015 | PLUMBING - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 12/11/2015 | ELECTRIC - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 12/11/2015 | BUILDING - PROGRESS | MRAMBER | Approved | IVRS - Inspection :* |
| 12/11/2015 | U VALUE FOR WINDOW | MRAMBER | Approved | IVRS - Inspection :* |
| 12/11/2015 | NPPO - FINAL | RLEDONNE | Approved | |
| 12/11/2015 | SIGN - FINAL | RLEDONNE | Approved | |
| 12/11/2015 | LANDSCAPE - FINAL | RLEDONNE | Approved | |
| 12/11/2015 | ENGINEERING - FINAL | RLEDONNE | Approved | |
| 12/28/2015 | FIRE SPKLR - FINAL | jvincent | Approved | CClark approved 12/07/15 |
| 12/30/2015 | BUILDING - FINAL | MRAMBER | Approved | 1. PROVIDE EGRESSAT BACK DOOR 2. COMPLETE FIRE APPROVALS |
| 12/30/2015 | FIRE - FINAL | jvincent | Approved | 1) Need 5yr check valve report. 2) Need fire alarm final. 3) Need solution for main exit door, exit discharge. 4) Move emergency light, main exit, hallway 177/184. 5) Need document stating inspector test is OK for NE riser. Doesn't appear to be reduced. 6) Depending on how supervisory switch for tamper is installed, lock on riser door may be required. |
| 12/30/2015 | FIRE - ALARM FINAL | jvincent | Approved | not ready |
| 02/03/2016 | REINFORCED MASONRY PRE-GROUT | MRAMBER | Approved | IVRS - Inspection :* |
| 02/03/2016 | BUILDING PRE-SLAB | MRAMBER | Approved | IVRS - Inspection :* |
| 02/03/2016 | STEM WALL/RETAINING WALL | MRAMBER | Approved | IVRS - Inspection :* |
| 02/03/2016 | EXCAVATION/LAYOUT REBAR & ZON | MRAMBER | Approved | IVRS - Inspection :* |