Permit: T15CM04663
Permit Details
Apply Date:
07/09/2015
Applicant:
DIANA FLYNN
Description:
NEW SHELL BUILDING
Contractors:
- DIVISION II CONSTRUCTION COMPANY
Permit Reviews
Permit Number - T15CM04663
Permit Status: Final
Permit Description: NEW SHELL BUILDING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/09/2015 | PLANS OK TO SUBMIT - COMM | 07/09/2015 | COMPLETED |
| 07/09/2015 | 3RD PARTY REVIEW - COMMERCIAL | 08/03/2015 | COMPLETED |
| 08/03/2015 | POST 3RD PARTY REVIEW | 08/11/2015 | COMPLETED |
| 11/17/2015 | OTHER | 12/15/2015 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T15CM04663
Permit Status: Final
Permit Description: NEW SHELL BUILDING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/09/2015 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T15CM04663
Permit Description: NEW SHELL BUILDING
Total Completed Inspections - 45
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/31/2015 | PLUMBING - ROUGH, SOIL | MPUGH | Approved | UNDER SLAB OK TO BACKFILL |
| 08/31/2015 | PLUMBING - ROUGH, SOIL | MPUGH1 | Approved | IVRS - Inspection :* |
| 09/11/2015 | EXCAVATION/LAYOUT REBAR & ZON | MPUGH | Approved | INTERIOR FOOTING MAT OK TO POOR |
| 09/11/2015 | EXCAVATION/LAYOUT REBAR & ZON | MPUGH1 | Approved | IVRS - Inspection :* |
| 09/17/2015 | BUILDING PRE-SLAB | RCAMACHO | Approved | IVRS - Inspection :* |
| 12/03/2015 | STEM WALL/RETAINING WALL | RCAMACHO | Approved | STAIRWELL FOOTINGS & STEMWALL AT ENTRYPER DETAIL 106 |
| 12/24/2015 | FRAMING | RCAMACHO | Approved | IVRS - Inspection :* |
| 12/24/2015 | ROOF NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
| 01/14/2016 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
| 01/14/2016 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
| 01/25/2016 | PLUMBING - GAS PRESSURE TEST | MRAMBER | Approved | IVRS - Inspection :* |
| 01/27/2016 | ELECTRIC - UNDERGROUND | RCAMACHO | Approved | IVRS - Inspection :* |
| 02/18/2016 | FIRE SPKLR - OH PIPING & HYDRO | jvincent | Approved | OH/hydro approved. 220>2hrs |
| 03/02/2016 | ELECTRIC - CABLE DROP | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/18/2016 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/18/2016 | PLUMBING - ROOF DRAINS | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/18/2016 | PLUMBING - YARD WTR LINE/TEST | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/18/2016 | ELECTRIC - OUTDOOR LIGHTING | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/18/2016 | U VALUE FOR WINDOW | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/18/2016 | ELECTRIC - UFER | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/18/2016 | MECHANICAL - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/18/2016 | PLUMBING - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/18/2016 | OUTDOOR LIGHTING FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/18/2016 | FIRE - ALARM FINAL | CBASALDUA | Approved | |
| 03/18/2016 | FIRE SPKLR - FINAL | CBASALDUA | Approved | |
| 03/18/2016 | FIRE SPKLR - UG PIPING FLUSH | CBASALDUA | Approved | |
| 03/18/2016 | FIRE SPKLR - UG, PIPING, HYDRO | CBASALDUA | Approved | |
| 03/18/2016 | FIRE - FINAL | CBASALDUA | Approved | |
| 03/21/2016 | RIGHT OF WAY - FINAL | JCASTRO | Approved | |
| 03/21/2016 | NPPO - FINAL | RLEDONNE | Approved | |
| 03/21/2016 | SIGN - FINAL | RLEDONNE | Approved | |
| 03/21/2016 | LANDSCAPE - FINAL | RLEDONNE | Approved | |
| 03/21/2016 | ENGINEERING - FINAL | RLEDONNE | Approved | |
| 03/23/2016 | BUILDING - FINAL | RCAMACHO | Approved | |
| 03/23/2016 | BUILDING ABOVE CEILING | RCAMACHO | Approved | |
| 03/23/2016 | ELECTRIC - CONSTRUCTION POWER | RCAMACHO | Approved | |
| 03/23/2016 | ELECTRIC - TEMPORARY SERVICE | RCAMACHO | Approved | |
| 03/23/2016 | ELECTRIC - SERVICE UPGRADE | RCAMACHO | Approved | |
| 03/23/2016 | PLUMBING - GAS PRESS TEST FNL | RCAMACHO | Approved | |
| 03/23/2016 | ELECTRIC - ABOVE CEILING | RCAMACHO | Approved | |
| 03/23/2016 | ELECTRIC - FINAL | RCAMACHO | Approved | |
| 03/23/2016 | PLUMBING - ABOVE CEILING | RCAMACHO | Approved | |
| 03/23/2016 | PLUMBING - SEWER HCS CONNECT | RCAMACHO | Approved | |
| 03/23/2016 | SITE - SEWER | RCAMACHO | Approved | |
| 03/23/2016 | MECHANICAL - ABOVE CEILING | RCAMACHO | Approved | PER FINAL |