Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address:
5632 E SPRING ST
Address NEW:
5632 E SPRING ST
Apply Date:
05/26/2015
Applicant:
KATHERINE STENDER
Description:
REMODEL MASTER BATH, FAMILY RM, LAUNDRY, PANTRY
Contractors:
  • J AND A GENERAL CONSTRUCTION L L C

Permit Reviews

Permit Number - T15CM03480
Permit Status: Expired
Permit Description: REMODEL MASTER BATH, FAMILY RM, LAUNDRY, PANTRY
Start Date Submittal Complete Date Status  
02/11/2016 REVISION - - 2ND 02/11/2016 ACTIVE Review Details
05/26/2015 RESIDENTIAL - BLDG/ZONING-WALKTHRU 05/26/2015 COMPLETED Review Details
06/08/2015 REVISION - - 1ST 02/11/2016 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T15CM03480
Permit Status: Expired
Permit Description: REMODEL MASTER BATH, FAMILY RM, LAUNDRY, PANTRY
Total Outstanding Activity Conditions - 1
Date Name
05/26/2015 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T15CM03480
Permite Description: REMODEL MASTER BATH, FAMILY RM, LAUNDRY, PANTRY
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
03/11/2016 BUILDING - FINAL N/A Not ready for Inspection IVRS - Inspection :* provide ladder, incomplete inspection
03/11/2016 ELECTRIC - FINAL N/A Not ready for Inspection IVRS - Inspection :* GFI' not working, no exposed bulbs in closets, and move light 12" off shelf front. 4 wire plug at dryer, receipts show open ground. incomplete inspection.
03/11/2016 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :* w/heater min. 3/4 T+P line, and line must run downhill.
03/11/2016 MECHANICAL - FINAL N/A Not ready for Inspection IVRS - Inspection :* provide back draft damper for dryer, Q: is new ductwork on roof insulated ?

Completed Inspections

Permit Status: Expired
Permit Number: T15CM03480
Permit Description: REMODEL MASTER BATH, FAMILY RM, LAUNDRY, PANTRY
Total Completed Inspections - 6
Date Description Inspector Results Comments
06/30/2015 EXT METAL CLIPS/EXT SHEATHING JMILITEL Approved OK TO INSULATE AND SHEET ROCK AREAS OTHER THAN MECHANICAL WORK TO BE DONE
06/30/2015 PLUMBING - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
06/30/2015 PLUMBING - ROUGH, SOIL JMILITEL Approved IVRS - Inspection :*
06/30/2015 ELECTRIC - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
06/30/2015 FRAMING JMILITEL Approved IVRS - Inspection :*
07/30/2015 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*

Documents

File Name Document Type  
001_RS-1.TIF CONSTRPLANS VIEW
002_AD-1.TIF CONSTRPLANS VIEW
003_A-1.TIF CONSTRPLANS VIEW
004_P-1.TIF CONSTRPLANS VIEW
005_E-1.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW