Permit Details

Status:
Expired
Type:
COMMERCIAL ALTERATION
Address NEW:
6100 E BROADWAY BL
Apply Date:
04/10/2015
Applicant:
PAGE, ROBERT ELWOOD
Description:
TI: INSTALL PAINT BOOTH
Architects:
  • PAGE, ROBERT ELWOOD
Contractors:
  • B G K CONSTRUCTION INC

Permit Reviews

Permit Number - T15CM02422
Permit Status: Expired
Permit Description: TI: INSTALL PAINT BOOTH
Start Date Submittal Complete Date Status  
04/10/2015 COMMERCIAL - TI 04/14/2015 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T15CM02422
Permit Status: Expired
Permit Description: TI: INSTALL PAINT BOOTH
Total Outstanding Activity Conditions - 1
Date Name
04/10/2015 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T15CM02422
Permite Description: TI: INSTALL PAINT BOOTH
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
08/18/2015 FIRE SPKLR - FINAL N/A Denied Need to monitor butterfly valve on piping to building sprinkler system locate outside northeast corner of building (sectional valve). IFC 903.4

Completed Inspections

Permit Status: Expired
Permit Number: T15CM02422
Permit Description: TI: INSTALL PAINT BOOTH
Total Completed Inspections - 11
Date Description Inspector Results Comments
06/19/2015 STEM WALL/RETAINING WALL JBURGE Approved IVRS - Inspection :*
06/19/2015 EXCAVATION/LAYOUT REBAR & ZON JBURGE Approved IVRS - Inspection :*
08/18/2015 PLUMBING - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
08/18/2015 ELECTRIC - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
08/18/2015 ELECTRIC - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
08/18/2015 ENGINEERING - FINAL MRUSSO Approved
08/19/2015 BUILDING - FINAL JMILITELLO Approved 10 PSI TEST IS OK. OK TO USE BOOTH
08/19/2015 PLUMBING - GAS PRESSURE TEST JMILITEL Approved IVRS - Inspection :*
08/19/2015 PLUMBING - FINAL JMILITEL Approved IVRS - Inspection :*
08/19/2015 ELECTRIC - FINAL JMILITEL Approved IVRS - Inspection :*
08/19/2015 BUILDING - FINAL JMILITEL Approved IVRS - Inspection :*

Documents

File Name Document Type  
INCORRECT ADDRESS.DOC CONSTRPLANS VIEW
001_0.1.TIF CONSTRPLANS VIEW
002_1.0.TIF CONSTRPLANS VIEW
003_MP1.TIF CONSTRPLANS VIEW
004_MP2.TIF CONSTRPLANS VIEW
005_E-1.TIF CONSTRPLANS VIEW
006_E-2.TIF CONSTRPLANS VIEW
007_CONST REFERENCE PLAN.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW