Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T14CM07937
Permit Details
Apply Date:
11/20/2014
Applicant:
RICHMOND AMERICAN CONSTRUCTION INC
Description:
SFR RICHT21L T13-M0035
Contractors:
- RICHMOND AMERICAN CONSTRUCTION INC
Permit Reviews
Permit Number - T14CM07937
Permit Status: Expired
Permit Description: SFR RICHT21L T13-M0035
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
11/20/2014 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 11/24/2014 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T14CM07937
Permit Status: Expired
Permit Description: SFR RICHT21L T13-M0035
Total Outstanding Activity Conditions - 4
Date | Name |
---|---|
11/20/2014 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
11/20/2014 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
11/20/2014 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
11/20/2014 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T14CM07937
Permit Description: SFR RICHT21L T13-M0035
Total Completed Inspections - 27
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/16/2014 | PLUMBING - SEWER HCS CONNECT | WLAHR | Approved | IVRS - Inspection :* |
12/16/2014 | PLUMBING - YARD WTR LINE/TEST | WLAHR | Approved | IVRS - Inspection :* |
12/16/2014 | PLUMBING - ROUGH, SOIL | WLAHR | Approved | IVRS - Inspection :* |
12/23/2014 | ELECTRIC - UFER | WLAHR | Approved | REBAR OK |
12/23/2014 | ELECTRIC - UNDERGROUND | WLAHR | Approved | IVRS - Inspection :* |
12/23/2014 | ELECTRIC - UFER | WLAHR | Approved | IVRS - Inspection :* |
12/23/2014 | BUILDING PRE-SLAB | WLAHR | Approved | IVRS - Inspection :* |
12/23/2014 | EXCAVATION/LAYOUT REBAR & ZON | WLAHR | Approved | IVRS - Inspection :* |
01/13/2015 | ROOF NAILING | WLAHR | Approved | IVRS - Inspection :* |
01/13/2015 | EXT METAL CLIPS/EXT SHEATHING | WLAHR | Approved | IVRS - Inspection :* |
01/27/2015 | MECHANICAL - INTERMEDIATE | RCANCINO | Approved | IVRS - Inspection :* |
01/27/2015 | PLUMBING - INTERMEDIATE | RCANCINO | Approved | IVRS - Inspection :* |
01/27/2015 | ELECTRIC - CONSTRUCTION POWER | RCANCINO | Approved | IVRS - Inspection :* |
01/27/2015 | PLUMBING - GAS PRESSURE TEST | RCANCINO | Approved | IVRS - Inspection :* |
01/27/2015 | ELECTRIC - INTERMEDIATE | RCANCINO | Approved | IVRS - Inspection :* |
01/27/2015 | U VALUE FOR WINDOW | RCANCINO | Approved | IVRS - Inspection :* |
01/27/2015 | STUCCO MESH | RCANCINO | Approved | IVRS - Inspection :* |
01/27/2015 | FRAMING | RCANCINO | Approved | IVRS - Inspection :* |
01/28/2015 | TEP CLEARANCE - AM | RCANCINO | Approved | ECO |
02/04/2015 | SHEET ROCK NAILING | WLAHR | Approved | IVRS - Inspection :* |
03/18/2015 | OUTDOOR LIGHTING FINAL | JBURGE | Approved | IVRS - Inspection :* |
03/19/2015 | GAS CLEARANCE | JBURGE | Approved | |
03/20/2015 | ELECTRIC - CABLE DROP | JBURGE | Approved | PER ELEC FINAL |
03/20/2015 | MECHANICAL - FINAL | JBURGE | Approved | IVRS - Inspection :* |
03/20/2015 | PLUMBING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
03/20/2015 | ELECTRIC - FINAL | JBURGE | Approved | IVRS - Inspection :* |
03/20/2015 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |