Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T14CM03998
Permit Details
Apply Date:
06/26/2014
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
TI: APARTMENT BUILDING # C
Architects:
- EGLIN, EVAN SAR
Contractors:
- TOFEL CONSTRUCTION
Outstanding Activity Conditions
Permit Number - T14CM03998
Permit Status: L of c
Permit Description: TI: APARTMENT BUILDING # C
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/26/2014 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: L of c
Permit Number: T14CM03998
Permit Description: TI: APARTMENT BUILDING # C
Total Completed Inspections - 31
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/23/2015 | STUCCO MESH | JBURGE | Approved | OK TO STUCCO |
03/23/2015 | STUCCO MESH | JBURGE | Approved | IVRS - Inspection :* |
05/13/2015 | FRAMING | JBURGE | Approved | UNIT #'S (ADA): 45, 49, AND 51 |
05/13/2015 | ELECTRIC - INTERMEDIATE | JBURGE | Approved | IVRS - Inspection :* |
05/13/2015 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* |
05/13/2015 | FRAMING | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | MECHANICAL - FINAL | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | MECHANICAL - INTERMEDIATE | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | MECHANICAL - HYDRONIC PIPING | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | MECHANICAL - UNDERGROUND | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | PLUMBING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | PLUMBING - PROGRESS | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | PLUMBING - YARD WTR LINE/TEST | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | PLUMBING - ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | PLUMBING - INTERMEDIATE | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | ELECTRIC - FINAL | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | U VALUE FOR WINDOW | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | EXT METAL CLIPS/EXT SHEATHING | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | BUILDING PRE-SLAB | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | STEM WALL/RETAINING WALL | JBURGE | Approved | IVRS - Inspection :* |
06/16/2015 | BUILDING - PROGRESS | JBURGE | Approved | IVRS - Inspection :* |
07/21/2015 | NPPO - FINAL | MRUSSO | Approved | |
07/21/2015 | SIGN - FINAL | MRUSSO | Approved | |
07/21/2015 | LANDSCAPE - FINAL | MRUSSO | Approved | |
07/21/2015 | ENGINEERING - FINAL | MRUSSO | Approved | |
07/23/2015 | RIGHT OF WAY - FINAL | JOSE CAZARES | Approved | |
07/30/2015 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | PER BLDG FINAL |
07/30/2015 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
07/30/2015 | FIRE - FINAL | Nsprenger | Approved | Added 1A:10B:C type extinguishers in each unit. All bedrooms and hallways have a battery operated smoke ( not interconnected ). The ADA rooms have strobe/horns interconnected in each bed and hallway. The lock on the SW exit from pool area is now a thumb turn bolt and there is a mesh wire screen around the lock to prevent little arms from reaching through the bars and accessing the lock. The old 911 phone has been removed. Emergency lights in the community room are operating correctly. Fire extinguisher in community room is provided. |