Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T14CM02729
Permit Details
Apply Date:
05/09/2014
Applicant:
YOUSEY, EARL CHARLES IV
Description:
ADD OFFICES, NEW ENTRY, RESTROOMS, & REMODEL - CHURCH
Architects:
- YOUSEY, EARL CHARLES IV
Contractors:
- LA CIMA CONSTRUCTION COMPANY L L C
Permit Reviews
Permit Number - T14CM02729
Permit Status: Expired
Permit Description: ADD OFFICES, NEW ENTRY, RESTROOMS, & REMODEL - CHURCH
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/14/2015 | COMMERCIAL - TI | 02/06/2015 | COMPLETED |
| 02/06/2015 | RESUBMITTAL | 02/25/2015 | COMPLETED |
| 03/13/2015 | REVISION - - 1ST | 03/13/2015 | COMPLETED |
| 05/01/2015 | REVISION - - 2ND | 08/14/2015 | COMPLETED |
| 05/09/2014 | COMMERCIAL - TI | 10/09/2014 | COMPLETED |
| 08/14/2015 | REVISION - - 3RD | 08/14/2015 | COMPLETED |
| 10/09/2014 | COMMERCIAL - TI | 11/18/2014 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T14CM02729
Permit Status: Expired
Permit Description: ADD OFFICES, NEW ENTRY, RESTROOMS, & REMODEL - CHURCH
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 05/09/2014 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 10/09/2014 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
| 10/09/2014 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
| 10/09/2014 | SPECIAL INSPECTION FOR PANELIZED ROOF STRUCTURES IS REQUIRED. |
| 10/09/2014 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 10/09/2014 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T14CM02729
Permite Description: ADD OFFICES, NEW ENTRY, RESTROOMS, & REMODEL - CHURCH
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| FIRE SPKLR - FINAL | N/A | Not Inspected | ||
| FIRE - ALARM FINAL | N/A | Not Inspected | ||
| RIGHT OF WAY - FINAL | N/A | Not Inspected | ||
| 04/01/2015 | BUILDING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* |
| 04/01/2015 | BUILDING - FINAL | N/A | Not ready for Inspection | WF 1-8 AT DOORS OK TO POUR, EXCEPT F7-0 FOOTERS PER DETAIL 404 |
| 05/27/2016 | ENGINEERING - FINAL | N/A | Partial Approval | OK FOR TEMPORARY C OF O |
| 12/18/2015 | FIRE - FINAL | N/A | Partial Approval | 1. TCO can be given for the new kitchen, bathrooms, and hallway once the following items are complete: a.) partition between finished sprinkler hallway and unfinished construction side. b.) ceiling tiles in place. c.) test emergency lights. |
Completed Inspections
Permit Status: Expired
Permit Number: T14CM02729
Permit Description: ADD OFFICES, NEW ENTRY, RESTROOMS, & REMODEL - CHURCH
Total Completed Inspections - 28
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/18/2015 | SITE - SEWER | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/18/2015 | PLUMBING - YARD WTR LINE/TEST | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/18/2015 | PLUMBING - ROUGH, SOIL | RCAMACHO | Approved | IVRS - Inspection :* |
| 03/26/2015 | BUILDING PRE-SLAB | RCAMACHO | Approved | IVRS - Inspection :* |
| 04/22/2015 | EXCAVATION/LAYOUT REBAR & ZON | IVR USER | Approved | IVRS - AP canceled |
| 06/24/2015 | ROOF NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
| 06/25/2015 | EXT METAL CLIPS/EXT SHEATHING | RCAMACHO | Approved | IVRS - Inspection :* |
| 07/20/2015 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
| 07/20/2015 | PLUMBING - GAS PRESSURE TEST | MRAMBER | Approved | IVRS - Inspection :* |
| 07/20/2015 | ELECTRIC - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
| 07/20/2015 | FRAMING | MRAMBER | Approved | IVRS - Inspection :* |
| 07/29/2015 | PLUMBING - ROOF DRAINS | RCAMACHO | Approved | IVRS - Inspection :* |
| 10/07/2015 | SHEET ROCK NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
| 10/12/2015 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
| 10/12/2015 | U VALUE FOR WINDOW | RCAMACHO | Approved | IVRS - Inspection :* |
| 10/12/2015 | STUCCO MESH | RCAMACHO | Approved | IVRS - Inspection :* |
| 12/08/2015 | BUILDING ABOVE CEILING | MRAMBER | Approved | PROVIDE INSULATION AT WH BVENT NEED GFCI AT RECIRC. PUMP COMPLETE SINK 3COMPARTMENT AT KITCHEN 3 ROOMS SOUTH WEST ABOVE CEILING TEMP C.O. PENDING ABOVE ITEMS |
| 12/08/2015 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 12/08/2015 | PLUMBING - PROGRESS | MRAMBER | Approved | IVRS - Inspection :* |
| 12/08/2015 | PLUMBING - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 12/08/2015 | ELECTRIC - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 01/14/2016 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 01/14/2016 | PLUMBING - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 01/14/2016 | ELECTRIC - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 01/14/2016 | ELECTRIC - OUTDOOR LIGHTING | MRAMBER | Approved | IVRS - Inspection :* |
| 05/27/2016 | NPPO - FINAL | DROBERTS | Approved | |
| 05/27/2016 | SIGN - FINAL | DROBERTS | Approved | |
| 05/27/2016 | LANDSCAPE - FINAL | DROBERTS | Approved |