Applicant:
LENNAR ARIZONA CONSTRUCTION INC
Description:
SFR LENN356313 T13-M0055
Contractors:
- LENNAR ARIZONA CONSTRUCTION INC
Permit Reviews
Permit Number - T14CM00016
Permit Status: Expired
Permit Description: SFR LENN356313 T13-M0055
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/02/2014 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 01/02/2014 | COMPLETED |
02/11/2014 | REVISION - WALK THRU | 02/11/2014 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T14CM00016
Permit Status: Expired
Permit Description: SFR LENN356313 T13-M0055
Total Outstanding Activity Conditions - 4
Date | Name |
---|---|
01/02/2014 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
01/02/2014 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
01/02/2014 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
01/02/2014 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T14CM00016
Permit Description: SFR LENN356313 T13-M0055
Total Completed Inspections - 27
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/06/2014 | PLUMBING - YARD WTR LINE/TEST | WLAHR | Approved | IVRS - Inspection :* |
01/06/2014 | PLUMBING - ROUGH, SOIL | WLAHR | Approved | IVRS - Inspection :* |
01/15/2014 | ELECTRIC - UNDERGROUND | WLAHR | Approved | IVRS - Inspection :* |
01/15/2014 | BUILDING PRE-SLAB | WLAHR | Approved | IVRS - Inspection :* |
01/15/2014 | EXCAVATION/LAYOUT REBAR & ZON | WLAHR | Approved | IVRS - Inspection :* |
02/03/2014 | ROOF NAILING | WLAHR | Approved | IVRS - Inspection :* |
02/03/2014 | EXT METAL CLIPS/EXT SHEATHING | WLAHR | Approved | IVRS - Inspection :* |
02/10/2014 | ELECTRIC - CABLE DROP | WLAHR | Approved | IVRS - Inspection :* |
02/10/2014 | ELECTRIC - CONSTRUCTION POWER | WLAHR | Approved | IVRS - Inspection :* |
02/10/2014 | ELECTRIC - UFER | WLAHR | Approved | IVRS - Inspection :* |
02/11/2014 | TEP CLEARANCE - AM | WLAHR | Approved | ECO |
02/11/2014 | PLUMBING - SEWER HCS CONNECT | WLAHR | Approved | IVRS - Inspection :* |
02/13/2014 | U VALUE FOR WINDOW | WLAHR | Approved | IVRS - Inspection :* |
02/13/2014 | STUCCO MESH | WLAHR | Approved | IVRS - Inspection :* |
02/13/2014 | PLUMBING - GAS PRESSURE TEST | WLAHR | Approved | IVRS - Inspection :* |
02/13/2014 | FRAMING | WLAHR | Approved | IVRS - Inspection :* |
02/13/2014 | MECHANICAL - INTERMEDIATE | WLAHR | Approved | IVRS - Inspection :* |
02/13/2014 | PLUMBING - INTERMEDIATE | WLAHR | Approved | IVRS - Inspection :* |
02/13/2014 | ELECTRIC - INTERMEDIATE | WLAHR | Approved | IVRS - Inspection :* |
02/20/2014 | SHEET ROCK NAILING | RCANCINO | Approved | |
03/18/2014 | OUTDOOR LIGHTING FINAL | WLAHR | Approved | IVRS - Inspection :* |
03/19/2014 | GAS CLEARANCE | WLAHR | Approved | |
03/20/2014 | MECHANICAL - ABOVE CEILING | WLAHR | Approved | PER MECH FINAL |
03/20/2014 | MECHANICAL - FINAL | WLAHR | Approved | IVRS - Inspection :* |
03/20/2014 | PLUMBING - FINAL | WLAHR | Approved | IVRS - Inspection :* |
03/20/2014 | ELECTRIC - FINAL | WLAHR | Approved | IVRS - Inspection :* |
03/20/2014 | BUILDING - FINAL | WLAHR | Approved | IVRS - Inspection :* |