Permit: T13CM07318
Permit Details
Apply Date:
12/04/2013
Applicant:
WENGER, GARY DEANE
Description:
REPAIR/REPLACE RAILINGS & WALKWAY SURFACES- APARTMENT COMPLEX
Architects:
- WENGER, GARY DEANE
Contractors:
- SIGMA CONTRACTING INC ,
Permit Reviews
Permit Number - T13CM07318
Permit Status: Expired
Permit Description: REPAIR/REPLACE RAILINGS & WALKWAY SURFACES- APARTMENT COMPLEX
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/25/2014 | REVISION - WALK THRU | 04/25/2014 | COMPLETED |
| 12/04/2013 | COMMERCIAL - BLDG/FIRE/ZONING/ENG | 12/04/2013 | COMPLETED |
| 12/04/2013 | COMMERCIAL - BLDG/FIRE/ZONING/ENG | 04/25/2014 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T13CM07318
Permit Status: Expired
Permit Description: REPAIR/REPLACE RAILINGS & WALKWAY SURFACES- APARTMENT COMPLEX
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 12/04/2013 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 12/26/2013 | SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. |
| 12/26/2013 | SPECIAL INSPECTION FOR CONCRETE IS REQUIRED.. |
| 12/26/2013 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
| 12/04/2013 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
| 12/26/2013 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T13CM07318
Permite Description: REPAIR/REPLACE RAILINGS & WALKWAY SURFACES- APARTMENT COMPLEX
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| REINFORCED MASONRY PRE-GROUT | N/A | Not Inspected | ||
| BUILDING - FINAL | N/A | Not Inspected | ||
| 07/17/2014 | BUILDING - PROGRESS | N/A | Partial Approval | IVRS - Inspection :* |
| 08/11/2014 | FRAMING | N/A | Partial Approval | IVRS - Inspection :* |
| 08/11/2014 | FRAMING | N/A | Partial Approval | SIDE STAIR OK INSTALL REMAINING POSTS FASTEN ALL SUPSON SUPPORTS PER SPACS |
| 10/08/2014 | FIRE - FINAL | N/A | Denied | TFC 2012 Edition Sec. 1008.1.9 Door Operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. - Many doors with new hardware have a deadbolt only on the outside, with the interior quarter turn mechanism unable to work. |
Completed Inspections
Permit Status: Expired
Permit Number: T13CM07318
Permit Description: REPAIR/REPLACE RAILINGS & WALKWAY SURFACES- APARTMENT COMPLEX
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/09/2014 | SIGN INSPECTION | RLEDONNE | Approved |