Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address NEW:
1695 W COCHRAN ST
Apply Date:
11/13/2013
Applicant:
KARLA ORTEGA
Description:
RECONNECT ELECTRIC

Outstanding Activity Conditions

Permit Number - T13CM06916
Permit Status: Final
Permit Description: RECONNECT ELECTRIC
Total Outstanding Activity Conditions - 1
Date Name
11/13/2013 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T13CM06916
Permit Description: RECONNECT ELECTRIC
Total Completed Inspections - 4
Date Description Inspector Results Comments
11/15/2013 ELECTRIC - FINAL RCAMACHO Approved 1. REPLACE MISSING HARDWARE SMOKE ALARM IN HALLWAY LIKE FOR LIKE
2. RELOCATE SMOKE ALARMS PER SPECS IN BEDROOMS. MINIMUM 36" FROM FORCED AIR REGISTERS. 6"-12" FROM CEILINGS.
3. SEAL OPENINGS IN DEAD FRONT IN SERVICE PANEL
11/15/2013 ELECTRIC - FINAL RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
11/15/2013 ELECTRIC - RECONNECT RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
01/09/2014 TEP CLEARANCE - AM RCAMACHO Approved RECN

Documents

File Name Document Type  
None DOCUMENTS VIEW