Permit: T13CM03955
Permit Details
Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
1441 S AVENIDA REGULO
Address NEW:
1441 S AVENIDA REGULO
Apply Date:
06/28/2013
Applicant:
BRIDGETT BALDWIN
Description:
RECONNECT ELECTRIC; RES
Outstanding Activity Conditions
Permit Number - T13CM03955
Permit Status: Final
Permit Description: RECONNECT ELECTRIC; RES
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/28/2013 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T13CM03955
Permit Description: RECONNECT ELECTRIC; RES
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/01/2013 | ELECTRIC - FINAL | RMORENO | Approved | 1. SERVICE PANEL MISSING DEAD FRONT COVERS 2. SUB-PANEL IN LAUNDRY ROOM MISSING COVERS TOO & TO BE READY ACCESSABLE & HAVE 3' CLEARANCE 3. REGENERATOR OUTLET MISSING COVER PLACE 4. OUTLETS BROKEN IN BEDROOMS 5. SMOKE DETECTORS TOO LOW & TOO CLOSE TO VENTS 6. DRAIN FOR WASHER MISSING 7. FRONT DOOR OUTSIDE LIGHTS NOT WIRED TO CODE 245 8. FAN IN BEDROOM NOT WIRED TO CODE 245 9. WIRES & BOXES TO BE CAPPED BLANCHED OFF OR REMOVED |
| 07/01/2013 | ELECTRIC - FINAL | RMORENO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 07/01/2013 | ELECTRIC - RECONNECT | RMORENO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 02/11/2014 | TEP CLEARANCE - AM | RMORENO | Approved | RECN |