Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
967 W CALLE MARGARITA
Apply Date:
06/03/2013
Applicant:
RITEWAY VENTILATING **APA**
Description:
INSTALL NEW 4 TON HEAT PUMP (APA)
Contractors:
  • RITEWAY VENTILATING **APA**

Permit Reviews

Permit Number - T13CM03346
Permit Status: Expired
Permit Description: INSTALL NEW 4 TON HEAT PUMP (APA)
Start Date Submittal Complete Date Status  
06/03/2013 WALK THRU - RES 06/03/2013 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T13CM03346
Permit Status: Expired
Permit Description: INSTALL NEW 4 TON HEAT PUMP (APA)
Total Outstanding Activity Conditions - 1
Date Name
06/03/2013 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T13CM03346
Permite Description: INSTALL NEW 4 TON HEAT PUMP (APA)
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
12/12/2013 MECHANICAL - INTERMEDIATE N/A Denied 1. WHITE WIRE NOT TO BE USED AS HOT LEG
2. CONDENSATE NOT PROPERLY TERMINATED
3. PROVIDE R-8 (2") INSULATION ON ROOFTOP DUCT
4. ALL PVC EXPOSED TO DAYLIGHT IS TO BE COATED FOR UV PROTECTION
5. PROVIDE BUSHING AT REAR OF DISCONNECT
12/12/2013 MECHANICAL - INTERMEDIATE N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/12/2013 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW