Permit: T13CM02128
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
4620 E CALLE CORTA
Address NEW:
4620 E CALLE CORTA
Apply Date:
04/10/2013
Applicant:
CARLOS ORTIZ
Description:
GAS LINE REPLACEMENT
Permit Reviews
Permit Number - T13CM02128
Permit Status: Expired
Permit Description: GAS LINE REPLACEMENT
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/10/2013 | RESIDENTIAL - BLDG/WWM | 04/10/2013 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T13CM02128
Permit Status: Expired
Permit Description: GAS LINE REPLACEMENT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/10/2013 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T13CM02128
Permite Description: GAS LINE REPLACEMENT
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/11/2013 | PLUMBING - FINAL | N/A | Partial Approval | 15 PSI TEST IS OK. LEFT GAS CARD. PROVIDE THE REQUIRED ELEC BOND TO THE GAS PIPING. PROVIDE 3 SCREWS IN ALL JOINTS OF WATER HEATER VENT CONNECTOR. TRACER WIRE NOT NECESSARY IN TRENCH WITH METAL PIPE. OK TO BACKFILL TRENCH RECALL FOR FINAL INSPECTION |
| 04/11/2013 | PLUMBING - FINAL | N/A | Partial Approval | IVRS - Inspection :* |
Completed Inspections
Permit Status: Expired
Permit Number: T13CM02128
Permit Description: GAS LINE REPLACEMENT
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/11/2013 | PLUMBING - GAS PRESSURE TEST | JMILITEL | Approved | IVRS - Inspection :* |