Permit: T12EL00361
Permit Details
Apply Date:
02/10/2012
Applicant:
RONALD HART
Description:
ELEC RECONNECT (RES)
Outstanding Activity Conditions
Permit Number - T12EL00361
Permit Status: Expired
Permit Description: ELEC RECONNECT (RES)
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
02/10/2012 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T12EL00361
Permite Description: ELEC RECONNECT (RES)
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
ELECTRIC - FINAL | N/A | Not Inspected | ||
02/13/2012 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECRUE ALL EXTERIOR CONDUIT TO CODE. CAP ALL JUNCTION BOXES 2) EXPOSED WIRING KITCHEN CABINETS, PROTECT FROM PHYSICAL DAMAGE OR OMIT 3) EXPOSED ROMEX BATH AND WATER HEATER ROOM 4) SMOKE ALARMS BEDROOMS AND HALLWAYS 5) ALL ADDITIONS SHOULD BE ON RECORD 6) HEADER HEIGHT 5' 8" BREAKTHROUGH LIVING ROOM TO KITCHEN OVERSPANNED 7) REMOVE ALL EXTERIOR EXPOSED ROMEX 8) AT ADDITION 2 X 4 RAFTERS OVERSPANNED 9) PLUMBING NOT MAINTAINED 10) STRUCTUAL CONDITIONS COULD MEAN BLDG DANGEROUS |