Permit Details

Status:
L of c
Type:
COMMERCIAL ALTERATION
Address NEW:
2920 N SWAN RD #114
Apply Date:
11/30/2012
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
TI: RESTAURANT
Contractors:
  • VENTURA PACIFIC DEVELOPMENT INC

Permit Reviews

Permit Number - T12CM07590
Permit Status: L of c
Permit Description: TI: RESTAURANT
Start Date Submittal Complete Date Status  
04/26/2013 RESUBMITTAL - TI ALL 05/07/2013 COMPLETED Review Details
05/07/2013 RESUBMITTAL 05/13/2013 COMPLETED Review Details
11/30/2012 PLANS OK TO SUBMIT - COMM 11/30/2012 COMPLETED Review Details
12/03/2012 COMMERCIAL - TI 01/03/2013 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T12CM07590
Permit Status: L of c
Permit Description: TI: RESTAURANT
Total Outstanding Activity Conditions - 1
Date Name
11/30/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: L of c
Permit Number: T12CM07590
Permit Description: TI: RESTAURANT
Total Completed Inspections - 43
Date Description Inspector Results Comments
06/14/2013 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection :*
06/17/2013 PLUMBING - PRE SLAB JMILITEL Approved OK TO RUN HOT WATER PIPING FROM BAR IN THE TRENCH
PER JIM
06/17/2013 ELECTRIC - UNDERGROUND JMILITEL Approved PER JIM
06/20/2013 BUILDING - PROGRESS JMILITEL Approved OK TO POUR FOOTING FOR MAT CLEANING AREA
06/20/2013 BUILDING - PROGRESS JMILITEL Approved IVRS - Inspection :*
07/26/2013 REINFORCED MASONRY PRE-GROUT JMILITEL Approved OK FOR TOP OUT ON WASHOUT WALL
OK TO PROCEED ON FIREPLACE
07/26/2013 REINFORCED MASONRY PRE-GROUT JMILITEL Approved IVRS - Inspection :*
08/15/2013 ELECTRIC - INTERMEDIATE JMILITEL Approved
08/15/2013 PLUMBING - INTERMEDIATE JMILITEL Approved PER JMILITELLO
OK TO SHEETROCK WALLS
08/27/2013 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
08/27/2013 SHEET ROCK NAILING JMILITEL Approved IVRS - Inspection :*
08/27/2013 MECHANICAL - INTERMEDIATE BSTEVENS Approved RESTROOM VENTS OK
08/27/2013 SHEET ROCK NAILING BSTEVENS Approved OK IN DINING & KITCHEN
11/19/2013 PLUMBING - GAS PRESSURE TEST JMILITEL Approved IVRS - Inspection :*
11/25/2013 MECHANICAL - HOODS JMILITEL Approved OK TO CLOSE CEILING IN KITCHEN
11/25/2013 MECHANICAL - HOODS JMILITEL Approved IVRS - Inspection :*
11/26/2013 NPPO - FINAL DROBERTS Approved
11/26/2013 LANDSCAPE - FINAL DROBERTS Approved
11/26/2013 ENGINEERING - FINAL DROBERTS Approved COMPLETE ALL AREAS PRIOR TO CALLING THIS INSPECTION IN FOR THE FINAL.
11/26/2013 RIGHT OF WAY - FINAL PW Approved
11/27/2013 OUTDOOR LIGHTING FINAL JMILITEL Approved IVRS - Inspection :*
11/27/2013 FIRE SPKLR - FINAL wmotto Approved
12/06/2013 SIGN - FINAL DROBERTS Approved
12/06/2013 FIRE - FINAL wmotto Approved 1. ok for temp c of o per tucsonfire.
2. ok to occupy per tucsonfire.
12/06/2013 FIRE - KITCHEN EXH HOOD FINAL wmotto Approved 1. hood has been tested and inspected everything works to the code. Just need it monitored.
12/06/2013 FIRE - ALARM FINAL wmotto Approved 1. just need alarm company to call in thier permit and monitor the hood.
12/11/2013 BUILDING - FINAL JMILITEL Approved PROVIDE ACCESS TO ROOF. PAINT EXPOSED BLACK IRON GREASE DUCTS ON ROOF. EXTEND WATER HEATER VENT 2' ABOVE EVAP COOLER & SECURE & SECURE WITH GUY WIRES. AIR BALANCE REPORT OK. PROPERLY SECURE PIZZA OVEN DUCT ON ROOF. SECURE ELEC CONDUITS ON ROOF.
12/11/2013 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
12/11/2013 PLUMBING - FINAL JMILITEL Approved IVRS - Inspection :*
12/11/2013 ELECTRIC - FINAL JMILITEL Approved IVRS - Inspection :*
12/11/2013 BUILDING - FINAL JMILITEL Approved IVRS - Inspection :*
01/30/2014 PLUMBING - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
01/30/2014 ELECTRIC - OUTDOOR LIGHTING JMILITEL Approved IVRS - Inspection :*
01/30/2014 ELECTRIC - PROGRESS JMILITEL Approved IVRS - Inspection :*
01/30/2014 ELECTRIC - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
01/30/2014 PLUMBING - PROGRESS JMILITEL Approved IVRS - Inspection :*
01/30/2014 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
01/30/2014 BUILDING ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
01/30/2014 FRAMING JMILITEL Approved IVRS - Inspection :*
02/25/2014 ELECTRIC - TEMPORARY SERVICE JMILITEL Approved PER FINAL
02/25/2014 ROOF NAILING JMILITEL Approved PER BLDG FINAL
02/25/2014 SITE - SEWER JMILITEL Approved IVRS - Inspection :*
02/26/2014 HEALTH DEPT - FINAL 724-7908 NRAMIREZ Approved APPROVED