Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Withdrwn
Type:
COMMERCIAL ALTERATION
Address NEW:
1145 E VALENCIA RD 01
Apply Date:
08/15/2012
Applicant:
GEORGE E. HOLGUIN
Description:
TI:TUCSON ROLLER DERBY
Architects:
  • GEORGE E. HOLGUIN
Contractors:
  • KELSARA CUSTOM BUILDERS L L C

Permit Reviews

Permit Number - T12CM05036
Permit Status: Withdrwn
Permit Description: TI:TUCSON ROLLER DERBY
Start Date Submittal Complete Date Status  
08/15/2012 COMMERCIAL - TI 08/17/2012 COMPLETED Review Details
09/14/2012 REVISION - - 1ST 09/14/2012 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T12CM05036
Permit Status: Withdrwn
Permit Description: TI:TUCSON ROLLER DERBY
Total Outstanding Activity Conditions - 1
Date Name
08/15/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Withdrwn
Permit Number: T12CM05036
Permite Description: TI:TUCSON ROLLER DERBY
Total Outstanding Inspections - 14
Last Inspection Date Description Inspector Results Comments
BUILDING ABOVE CEILING N/A Not Inspected
SHEET ROCK NAILING N/A Not Inspected
BUILDING - FINAL N/A Not Inspected
PLUMBING - ABOVE CEILING N/A Not Inspected
PLUMBING - PROGRESS N/A Not Inspected
MECHANICAL - INTERMEDIATE N/A Not Inspected
MECHANICAL - ABOVE CEILING N/A Not Inspected
MECHANICAL - FINAL N/A Not Inspected
FIRE SPKLR - FINAL N/A Not Inspected
FIRE - ALARM FINAL N/A Not Inspected
03/27/2013 ELECTRIC - INTERMEDIATE N/A Not ready for Inspection IVRS - Inspection :*
03/29/2013 ELECTRIC - FINAL N/A Not ready for Inspection IVRS - Inspection :*
03/29/2013 PLUMBING - INTERMEDIATE N/A Not ready for Inspection IVRS - Inspection :*
12/07/2012 FRAMING N/A Partial Approval 1) 2X4 STUDS ALONG EAST WALL HAVE BEEN NOTCHED BEYOND MAX ALLOWALE DEPTH, REPAIR OR REPLACE.
2) NO SHEET ROCK IS TO BE INSTALLED UNTIL PLUM AND ELEC. INSTPECTIONS HAVE BEEN APPROVED.

Completed Inspections

Permit Status: Withdrwn
Permit Number: T12CM05036
Permit Description: TI:TUCSON ROLLER DERBY
Total Completed Inspections - 3
Date Description Inspector Results Comments
11/01/2012 SITE - SEWER MRAMBER Approved IVRS - Inspection :*
11/01/2012 PLUMBING - PRE SLAB MRAMBER Approved IVRS - Inspection :*
11/01/2012 PLUMBING - ROUGH, SOIL MRAMBER Approved IVRS - Inspection :*

Documents

File Name Document Type  
None CONSTRPLANS VIEW
001_CVR.TIF CONSTRPLANS VIEW
002_SD-1.TIF CONSTRPLANS VIEW
003_A1.TIF CONSTRPLANS VIEW
004_A2.TIF CONSTRPLANS VIEW
005_A3.TIF CONSTRPLANS VIEW
006_A4.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW