Description:
RECONNECT:ELECTRIC:RES / ABATE HAZARDOUS CONDITIONS

Outstanding Activity Conditions

Permit Number - T12CM04923
Permit Status: Expired
Permit Description: RECONNECT:ELECTRIC:RES / ABATE HAZARDOUS CONDITIONS
Total Outstanding Activity Conditions - 1
Date Name
08/09/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T12CM04923
Permite Description: RECONNECT:ELECTRIC:RES / ABATE HAZARDOUS CONDITIONS
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
04/02/2013 BUILDING - FINAL N/A Partial Approval NEED TO VERIFY REAR SLIDING DOOR THAT WAS INSTALLED ON UPPER FLOOR WITHOUT PERMIT HAS BEEN RETURNED TO A NORMAL WINDOW UNIT.

Completed Inspections

Permit Status: Expired
Permit Number: T12CM04923
Permit Description: RECONNECT:ELECTRIC:RES / ABATE HAZARDOUS CONDITIONS
Total Completed Inspections - 4
Date Description Inspector Results Comments
08/16/2012 ELECTRIC - RECONNECT LHANLY Approved ELECTRICAL RECONNECT CANNOT BE APPROVED BECAUSE THIS IS A DANGEROUS BUILDING AS DEFINED IN THE CITY OF TUCSON NEIGHBORHOOD PRESERVATION ORDINANCE. HAZARDS ARE AS FOLLOWS.

1) Rear yard has been excavated exposing bottom of footings at the south-west corner of the building.

2) Retaining walls have been removed, and excavation of rear yard has exposed the bottom of footings for the east and west neighbors patio walls.

3) A wooden shed has been constructed on the east side of the building in violation of fire code setbacks, and is a structural hazard due to overspanned rafters.

4) The electrical service has been relocated without keeping the electrode grounding system intact. Also service has been re-mounted higher than allowed by code or TEP. Owner to verify where TEP will require service relocation.

5) A rear deck has been added onto the building without meeting minimum structural requirements, and without being maintained. The beams are undersized, the decking is rotting, the footings were never properly installed and have had their sides excavated away. Plywood was placed over rotting decking for a floor surface but is now delaminating and constitutes a fire hazard.

6) The stairs on the west side of the building have been modified with an added stair up to the rear deck. a) The modification to the landing does not meet minimum code requirements for structural stability and has rotted untreated lumber in contact or too close too earth. b) The undersized stair stringer to the deck has a major longitudinal split. c) Replaced treads and modified stringers do not meet rise and run requirements of code.
08/21/2012 ELECTRIC - FINAL LHANLY Approved SPOKE TO OWNER ABOUT HAZARDOUS BUILDING CONDITIONS. HE IS GOING TO HAVE A STRUCTURAL ENGINEER LOOK AT CONDITIONS AND THEN WILL OBTAIN REPAIR PERMIT.
04/02/2013 BUILDING - PROGRESS LHANLY Approved STRUCTURAL HAZARDS REMOVED
04/03/2013 TEP CLEARANCE - AM LHANLY Approved ECO