Permit: T12CM04479
Permit Details
Apply Date:
07/24/2012
Applicant:
DAVID PLOTKIN
Description:
TI: OFFICE
Contractors:
- SUNDT CONSTRUCTION
Permit Reviews
Permit Number - T12CM04479
Permit Status: C of o
Permit Description: TI: OFFICE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/24/2012 | COMMERCIAL - TI | 07/27/2012 | COMPLETED |
07/27/2012 | COMMERCIAL - TI | 08/24/2012 | COMPLETED |
09/05/2012 | RESUBMITTAL | 09/14/2012 | COMPLETED |
09/14/2012 | RESUBMITTAL | 09/18/2012 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T12CM04479
Permit Status: C of o
Permit Description: TI: OFFICE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/24/2012 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T12CM04479
Permit Description: TI: OFFICE
Total Completed Inspections - 39
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/02/2012 | PLUMBING - PRE SLAB | RMYERS | Approved | 1. No test on piping. 2. Add footings to permit. 3. Cap off all open piping. 4. Support all piping. 5. At shower: OK to cover this area only. 6. Columns at Break Room Canopy OK. |
11/13/2012 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* |
11/15/2012 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | |
11/19/2012 | MECHANICAL - INTERMEDIATE | RMYERS | Approved | 1. Mechanical above ceiling OK to insulate. |
11/30/2012 | ELECTRIC - OUTDOOR LIGHTING | MPUGH | Approved | IVRS - Inspection :* |
12/05/2012 | ELECTRIC - UNDERGROUND | MPUGH | Approved | IVRS - Inspection :* OK TO SHEETROCK WALLS WITH NO PLUMBING OR ELECTRIC. ALL PLUMBING OR ELECTRIC IN WALLS THAT IS ALREADY COVERED TO BE EXPOSED FOR INSPECTION, OR PROVIDE INSPECTION HISTORY FOR PLUMBING AND ELECTRIC. UNABLE TO LOCATE INSPECTION HISTORY OR PERMIT IN OFFICE |
12/05/2012 | FRAMING | MPUGH | Approved | IVRS - Inspection :* |
12/07/2012 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :* |
12/07/2012 | ELECTRIC - PROGRESS | RMYERS | Approved | IVRS - Inspection :* |
12/07/2012 | EXT METAL CLIPS/EXT SHEATHING | RMYERS | Approved | IVRS - Inspection :* |
12/14/2012 | SHEET ROCK NAILING | RMYERS | Approved | 1. All areas except centrally located "House" |
12/31/2012 | REINFORCED MASONRY PRE-GROUT | RMYERS | Approved | |
01/09/2013 | ROOF NAILING | RMYERS | Approved | |
01/09/2013 | U VALUE FOR WINDOW | RMYERS | Approved | |
01/24/2013 | FIRE SPKLR - UG PIPING FLUSH | CBASALDU | Approved | |
01/24/2013 | FIRE SPKLR - UG, PIPING, HYDRO | CBASALDU | Approved | |
02/04/2013 | PLUMBING - ABOVE CEILING | MPUGH | Approved | IVRS - Inspection :* |
02/04/2013 | ELECTRIC - ABOVE CEILING | MPUGH | Approved | IVRS - Inspection :* |
02/04/2013 | BUILDING ABOVE CEILING | MPUGH | Approved | IVRS - Inspection :* |
02/15/2013 | BUILDING - PROGRESS | RMYERS | Approved | CONTRACTOR REQUESTING TEMP C OF O EVERYTHING IS FUNCTIONAL JUST NOT COMPLETE |
02/15/2013 | ELECTRIC - SERVICE UPGRADE | RMYERS | Approved | |
02/19/2013 | TEP CLEARANCE - AM | RMYERS | Approved | INCR |
02/20/2013 | RIGHT OF WAY - FINAL | TWOLFGAN | Approved | |
02/20/2013 | FIRE SPKLR - OH PIPING & HYDRO | CBASALDU | Approved | |
02/22/2013 | FIRE SPKLR - FINAL | CBASALDU | Approved | |
02/22/2013 | OUTDOOR LIGHTING FINAL | MPUGH | Approved | IVRS - Inspection :* |
02/22/2013 | ELECTRIC - FINAL | MPUGH | Approved | IVRS - Inspection :* |
02/22/2013 | ELECTRIC - INTERMEDIATE | MPUGH | Approved | IVRS - Inspection :* |
02/22/2013 | ELECTRIC - UFER | MPUGH | Approved | IVRS - Inspection :* |
02/25/2013 | EXCAVATION/LAYOUT REBAR & ZON | MPUGH | Approved | |
02/25/2013 | PLUMBING - GAS PRESSURE TEST | MPUGH | Approved | |
02/25/2013 | MECHANICAL - FINAL | MPUGH | Approved | IVRS - Inspection :* |
02/25/2013 | PLUMBING - FINAL | MPUGH | Approved | IVRS - Inspection :* |
02/25/2013 | PLUMBING - BACK WATER VALVE | MPUGH | Approved | IVRS - Inspection :* |
02/25/2013 | BUILDING - FINAL | MPUGH | Approved | IVRS - Inspection :* |
02/26/2013 | FIRE - FINAL | WMOTTO | Approved | |
02/26/2013 | FIRE - ALARM FINAL | WMOTTO | Approved | |
03/06/2013 | ENGINEERING - FINAL | DROBERTS | Approved | |
03/06/2013 | LANDSCAPE - FINAL | DROBERTS | Approved |