Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T12CM04333
Permit Details
Apply Date:
07/18/2012
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
CLUBHOUSE
Contractors:
- MCCW BUILDERS LLC
Permit Reviews
Permit Number - T12CM04333
Permit Status: C of o
Permit Description: CLUBHOUSE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/05/2015 | REVISION - - 1ST | 05/05/2015 | COMPLETED |
05/05/2015 | REVISION - - 1ST | 08/18/2015 | COMPLETED |
07/18/2012 | PLANS OK TO SUBMIT - COMM | 07/18/2012 | COMPLETED |
07/23/2012 | COMMERCIAL - NEW | 08/30/2012 | COMPLETED |
08/30/2012 | RESUBMITTAL | 09/14/2012 | COMPLETED |
09/14/2012 | RESUBMITTAL | 10/04/2012 | COMPLETED |
10/04/2012 | RESUBMITTAL | 11/06/2012 | COMPLETED |
10/14/2014 | RESUBMITTAL | 10/28/2014 | COMPLETED |
11/06/2012 | RESUBMITTAL | 09/03/2014 | COMPLETED |
11/07/2014 | OTHER | 03/02/2015 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T12CM04333
Permit Status: C of o
Permit Description: CLUBHOUSE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/18/2012 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T12CM04333
Permit Description: CLUBHOUSE
Total Completed Inspections - 53
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/10/2015 | REINFORCED MASONRY PRE-GROUT | JBURGE | Approved | RETAINING WALL "D" AT 16"-68", APPROX 200' |
04/10/2015 | REINFORCED MASONRY PRE-GROUT | JBURGE | Approved | IVRS - Inspection :* |
04/13/2015 | PLUMBING - ROUGH, SOIL | JBURGE | Approved | BUILDING #14 - ROUGH SOIL - OK TO COVER |
04/13/2015 | PLUMBING - ROUGH, SOIL | JBURGE | Approved | IVRS - Inspection :* |
04/30/2015 | ELECTRIC - UNDERGROUND | JBURGE | Approved | OK TO COVER STUB - UPS TO BUILDING |
04/30/2015 | ELECTRIC - UNDERGROUND | JBURGE | Approved | IVRS - Inspection :* |
05/05/2015 | ELECTRIC - UFER | JBURGE | Approved | OK TO POUR |
05/05/2015 | BUILDING PRE-SLAB | JBURGE | Approved | RECEIVED OK FROM ARCHITECT (1145 HOURS) COLUMN FOOTING C5/F1 - PLUMBING WASTE LINES PRESENT IN COLUMN - NEED APPROVAL OF ENGINEER IN ORDER TO POUR SLAB |
05/05/2015 | PLUMBING - PRE SLAB | JBURGE | Approved | IVRS - Inspection :* |
05/05/2015 | ELECTRIC - UFER | JBURGE | Approved | IVRS - Inspection :* |
05/05/2015 | BUILDING PRE-SLAB | JBURGE | Approved | IVRS - Inspection :* |
06/19/2015 | ELECTRIC - OUTDOOR LIGHTING | RMORENO | Approved | 1 SITE LIGHTING FOR 2 BUILDING # 2, #3, U. G. OK 3/4 PVC 2.300FEET FOR TEMP IN TRENCH OK. |
06/19/2015 | ELECTRIC - OUTDOOR LIGHTING | RMORENO | Approved | IVRS - Inspection :* |
06/30/2015 | EXT METAL CLIPS/EXT SHEATHING | JBURGE | Approved | IVRS - Inspection :* |
06/30/2015 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* |
07/28/2015 | BUILDING - PROGRESS | JBURGE | Approved | PANEL ROOM, MAIN ENTRY FOYER, OK TO SET CAN LIGHTS AND SHEET ROCK |
07/31/2015 | PLUMBING - SEWER HCS CONNECT | JBURGE | Approved | IVRS - Inspection :* |
08/10/2015 | PLUMBING - PROGRESS | JBURGE | Approved | VACUUM TEST ON MANHOLE #1. ENGINEER OF RECORD PRESENT |
08/10/2015 | FIRE - HYDRANTS | CSCHULTZ | Approved | Hydrants in place and in service |
08/10/2015 | PLUMBING - PROGRESS | JBURGE | Approved | IVRS - Inspection :* |
08/17/2015 | FRAMING | JBURGE | Approved | OK TO INSULATE AND SHEETROCK WALLS |
08/17/2015 | MECHANICAL - INTERMEDIATE | JBURGE | Approved | IVRS - Inspection :* |
08/17/2015 | PLUMBING - INTERMEDIATE | JBURGE | Approved | IVRS - Inspection :* |
08/17/2015 | ELECTRIC - INTERMEDIATE | JBURGE | Approved | IVRS - Inspection :* |
08/17/2015 | FRAMING | JBURGE | Approved | IVRS - Inspection :* |
08/27/2015 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* |
08/27/2015 | STUCCO MESH | JBURGE | Approved | IVRS - Inspection :* |
11/16/2015 | PLUMBING - GAS PRESSURE TEST | JBURGE | Approved | IVRS - Inspection :* |
11/17/2015 | GAS CLEARANCE | JBURGE | Approved | |
12/16/2015 | ELECTRIC - TEMPORARY SERVICE | JBURGE | Approved | IVRS - Inspection :* |
12/17/2015 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | GATE COLUMNS (2) OK TO POUR PROGRESS AREA |
01/27/2016 | FIRE - ALARM FINAL | CClark1 | Approved | |
01/27/2016 | FIRE SPKLR - FINAL | CClark1 | Approved | |
01/27/2016 | FIRE - FINAL | CClark1 | Approved | |
01/28/2016 | MECHANICAL - ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* |
01/28/2016 | PLUMBING - YARD WTR LINE/TEST | JBURGE | Approved | IVRS - Inspection :* |
01/28/2016 | PLUMBING - ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* |
01/28/2016 | OUTDOOR LIGHTING FINAL | JBURGE | Approved | IVRS - Inspection :* |
01/28/2016 | ELECTRIC - ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* |
01/28/2016 | FIREWALL/FIREBARRIER/FIRESTOP | JBURGE | Approved | IVRS - Inspection :* |
01/28/2016 | U VALUE FOR WINDOW | JBURGE | Approved | IVRS - Inspection :* |
01/28/2016 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* |
01/28/2016 | MECHANICAL - FINAL | JBURGE | Approved | IVRS - Inspection :* |
01/28/2016 | PLUMBING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
01/28/2016 | ELECTRIC - FINAL | JBURGE | Approved | IVRS - Inspection :* |
02/02/2016 | FIRE - LANE SIGNS | cclark | Approved | |
02/08/2016 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
02/09/2016 | PLUMBING - ROOF DRAINS | JBURGE | Approved | |
02/09/2016 | RIGHT OF WAY - FINAL | DROBERTSON | Approved | |
03/02/2016 | NPPO - FINAL | DROBERTS | Approved | |
03/02/2016 | SIGN - FINAL | DROBERTS | Approved | |
03/02/2016 | LANDSCAPE - FINAL | DROBERTS | Approved | |
03/02/2016 | ENGINEERING - FINAL | DROBERTS | Approved |