Permit Details

Status:
C of o
Type:
MULTI FAMILY NEW
Address NEW:
345 E CONGRESS ST
Apply Date:
04/19/2012
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
STUDENT HOUSING
Contractors:
  • SUMMIT BUILDERS ,

Permit Reviews

Permit Number - T12CM02063
Permit Status: C of o
Permit Description: STUDENT HOUSING
Start Date Submittal Complete Date Status  
04/19/2012 PLANS OK TO SUBMIT - COMM 04/19/2012 COMPLETED Review Details
04/19/2012 COMMERCIAL - NEW 06/26/2012 COMPLETED Review Details
06/13/2012 RESUBMITTAL 07/31/2012 COMPLETED Review Details
07/31/2012 RESUBMITTAL 08/30/2012 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T12CM02063
Permit Description: STUDENT HOUSING
Total Completed Inspections - 46
Date Description Inspector Results Comments
11/19/2012 PLUMBING - PRE SLAB LHANLY Approved
11/19/2012 PLUMBING - ROUGH, SOIL LHANLY Approved
11/19/2012 ROOF NAILING LHANLY Approved
11/19/2012 BUILDING PRE-SLAB LHANLY Approved OK TO PLACE GYP-CRETE AT TUBS AND VOIDS
11/19/2012 STEM WALL/RETAINING WALL LHANLY Approved
11/19/2012 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved
12/12/2012 FRAMING LHANLY Approved
12/14/2012 PLUMBING - PROGRESS LHANLY Approved
12/14/2012 PLUMBING - ABOVE CEILING LHANLY Approved
12/14/2012 EXT METAL CLIPS/EXT SHEATHING LHANLY Approved COURTYARD LEVEL 5 ALL AROUND
COURTYARD LEVEL 6 E,S,N ONLY
COURTYARD LEVEL 7 E ONLY
12/14/2012 REINFORCED MASONRY PRE-GROUT LHANLY Approved PROGRESS TO LEVEL 7 OK
12/24/2012 PLUMBING - INTERMEDIATE RMYERS Approved 1. 6th and 7th floor PVC DWV in walls and overhead.
03/12/2013 U VALUE FOR WINDOW LHANLY Approved
03/12/2013 STUCCO MESH LHANLY Approved
03/12/2013 BUILDING ABOVE CEILING LHANLY Approved
05/06/2013 PLUMBING - YARD WTR LINE/TEST LHANLY Approved
05/06/2013 PLUMBING - ROOF DRAINS LHANLY Approved
05/06/2013 MECHANICAL - INTERMEDIATE LHANLY Approved
05/29/2013 ELECTRIC - UNDERGROUND LHANLY Approved
05/29/2013 ELECTRIC - UFER LHANLY Approved
05/29/2013 SHEET ROCK NAILING LHANLY Approved
07/03/2013 TEP CLEARANCE - AM LHANLY Approved 1303-1306
1403-1406
1509-1523
1609-1623
1709-1723
07/08/2013 MECHANICAL - ABOVE CEILING LHANLY Approved
07/08/2013 ELECTRIC - TEMPORARY SERVICE LHANLY Approved
07/08/2013 ELECTRIC - CABLE DROP LHANLY Approved
07/19/2013 PLUMBING - GAS PRESS TEST FNL LHANLY Approved
07/19/2013 PLUMBING - GAS PRESSURE TEST LHANLY Approved
07/19/2013 PLUMBING - GAS PRESS TEST FNL LHANLY Approved
07/19/2013 PLUMBING - GAS PRESSURE TEST LHANLY Approved
07/19/2013 ELECTRIC - PROGRESS LHANLY Approved
07/19/2013 ELECTRIC - ABOVE CEILING LHANLY Approved
07/19/2013 ELECTRIC - INTERMEDIATE LHANLY Approved
07/19/2013 ELECTRIC - ABOVE CEILING LHANLY Approved
07/19/2013 ELECTRIC - INTERMEDIATE LHANLY Approved
07/23/2013 FIRE - ALARM FINAL CBASALDU Approved
07/30/2013 FIRE SPKLR - FINAL CBASALDU Approved
07/30/2013 FIRE SPKLR - OH PIPING & HYDRO CBASALDU Approved
08/14/2013 FIREWALL/FIREBARRIER/FIRESTOP LHANLY Approved
08/14/2013 PLUMBING - FINAL LHANLY Approved
08/14/2013 MECHANICAL - FINAL LHANLY Approved
08/14/2013 BUILDING - PROGRESS LHANLY Approved
08/14/2013 BUILDING - PROGRESS LHANLY Approved
08/14/2013 FIREWALL/FIREBARRIER/FIRESTOP LHANLY Approved FIRESTOP IN ELECTRIC ROOMS INCOMPLETE
08/16/2013 FIRE - FINAL CBASALDU Approved
11/19/2013 ELECTRIC - FINAL JMANCHESTER Approved
11/19/2013 BUILDING - FINAL LHANLY Approved