Permit: T12CM01019
Permit Details
Apply Date:
03/12/2012
Applicant:
JEREMY COLLINS
Description:
REPAIR ELECTRICAL RISER- RES
Permit Reviews
Permit Number - T12CM01019
Permit Status: Final
Permit Description: REPAIR ELECTRICAL RISER- RES
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/12/2012 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 03/12/2012 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T12CM01019
Permit Status: Final
Permit Description: REPAIR ELECTRICAL RISER- RES
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/12/2012 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T12CM01019
Permit Description: REPAIR ELECTRICAL RISER- RES
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/29/2009 | ELECTRIC - FINAL | DQUINN | Approved | COMMENTS TRANSFERRED FROM: T09EL01226- IVRS - Inspection :* 1) PROTECT WIRES IN WALLS IN STORE ROOM, COVER WITH SHEETROCK OR PLY, ETC... 2) NEED OPERABLE SMOKE DETECTORS IN ALL BEDROOMS AND HALLWAY AT LEAST 3' FROM REGISTERS AND BETWEEN 6" + 12" OF CEILING IF WALL MOUNTED 3) RECALL WHEN DONE FOR FINAL |
| 03/14/2012 | TEP CLEARANCE - AM | JWEATHER | Approved | RECN CLEARED PER D. SANTACRUZ |
| 03/16/2012 | ELECTRIC - SERVICE UPGRADE | RHOLLAND | Approved | IVRS - Inspection :* |