Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
1634 S VIA HONDO
Address NEW:
1634 S VIA HONDO
Apply Date:
02/14/2012
Applicant:
DESERT HILLS ELECTRIC INC
Description:
UPGRADE: ELECTRIC TO 200 AMPS - RES
Contractors:
  • DESERT HILLS ELECTRIC INC

Outstanding Activity Conditions

Permit Number - T12CM00377
Permit Status: Final
Permit Description: UPGRADE: ELECTRIC TO 200 AMPS - RES
Total Outstanding Activity Conditions - 1
Date Name
02/14/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T12CM00377
Permit Description: UPGRADE: ELECTRIC TO 200 AMPS - RES
Total Completed Inspections - 3
Date Description Inspector Results Comments
02/27/2012 ELECTRIC - SERVICE UPGRADE MRAMBER Approved IVRS - Inspection :*
1) RELOCATE UFER ROD NEXT TO STRUCTURE OR SINK BELOW GRADE AS IT IS A SAFETY ISSUE
2) GROUND WIRING NOT PROPERLY STRAPPED TO STRUCTURE AND IS A TRIP HAZARD
02/28/2012 TEP CLEARANCE - AM JWEATHER Approved INCR CLEARED PER M. RAMBER
03/09/2012 ELECTRIC - FINAL RCAMACHO Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW