Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Apply Date:
01/09/2012
Applicant:
ECONOMY PLUMBING SERVICE L L C
Description:
REPLACE GAS LINES, SPLIT SYSTEM & WATER HEATER- RES
Contractors:
  • ECONOMY PLUMBING SERVICE L L C

Permit Reviews

Permit Number - T12CM00047
Permit Status: Expired
Permit Description: REPLACE GAS LINES, SPLIT SYSTEM & WATER HEATER- RES
Start Date Submittal Complete Date Status  
01/09/2012 OTHER 01/09/2012 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T12CM00047
Permit Status: Expired
Permit Description: REPLACE GAS LINES, SPLIT SYSTEM & WATER HEATER- RES
Total Outstanding Activity Conditions - 1
Date Name
01/09/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T12CM00047
Permite Description: REPLACE GAS LINES, SPLIT SYSTEM & WATER HEATER- RES
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
01/10/2012 MECHANICAL - INTERMEDIATE N/A Not ready for Inspection IVRS - Inspection :*
01/10/2012 MECHANICAL - FINAL N/A Not ready for Inspection IVRS - Inspection :*
1) PROVIDE APPROVED BARRIER BETWEEN FURNACE CLOSET AND BEDROOM
2) CONDENSATE TO TERMINATE AT AN APPROVED LOCATION
3) ALL PVC JOINTS TO HAVE PRIMER PRIOR TO GLUE
4) PROVIDE MINIMUM CLEARANCE TO COMBUSTIBELS AT VENT PIPING, PROVIDE APPROVED VENT CAP
5) PROVIDE SECONDARY DRAIN
6) PROVIDE PROTECTIVE CONDUIT ON EXTERIOR T-STAT WIRE
7) PROVIDE INSULATION (COATED) ON LINE SETS

Completed Inspections

Permit Status: Expired
Permit Number: T12CM00047
Permit Description: REPLACE GAS LINES, SPLIT SYSTEM & WATER HEATER- RES
Total Completed Inspections - 2
Date Description Inspector Results Comments
01/10/2012 PLUMBING - FINAL MRAMBER Approved IVRS - Inspection :*
01/10/2012 PLUMBING - GAS PRESSURE TEST MRAMBER Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW