Permit: T11ME00332
Permit Details
Apply Date:
12/16/2011
Applicant:
HALL TJ
Description:
REPLACE EXISTING 5 TON GAS PACKAGE UNIT-RES (VH)
Contractors:
- A R S AMERICAN RESIDENTIAL SERVICES *APA*
Outstanding Activity Conditions
Permit Number - T11ME00332
Permit Status: Final
Permit Description: REPLACE EXISTING 5 TON GAS PACKAGE UNIT-RES (VH)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/16/2011 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T11ME00332
Permit Description: REPLACE EXISTING 5 TON GAS PACKAGE UNIT-RES (VH)
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2011 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection : See detailed listing on site.| 999* DO NOT MOUNT DISCONNECT TO A SERVICE PANEL. BLOCK + CLAMP GAS LINE. SECURE ANGLE IRON STAND TO ROOF. USE PURPLE PRIMER ON ALL PVC FITTINGS PRIOR TO GLUE. PAINT ALL EXPOSED PVC W/LATEX PAINT |
| 12/22/2011 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection : See detailed listing on site.| 999* |