Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
2022 E SILVOSA ST
Apply Date:
12/12/2011
Applicant:
LIBRADA MONREAL
Description:
RECONNECT:ELECTRIC:RES

Outstanding Activity Conditions

Permit Number - T11EL03202
Permit Status: Expired
Permit Description: RECONNECT:ELECTRIC:RES
Total Outstanding Activity Conditions - 1
Date Name
12/12/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T11EL03202
Permite Description: RECONNECT:ELECTRIC:RES
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
12/14/2011 ELECTRIC - RECONNECT N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) THIS IS AN UNGROUNDED SYSTEM, REMOVE ALL GROUNDED OUTLETS AND REPLACE WITH UN-GROUNDED OUTLETS
2) BAR WIRES HANGING OUT OF FRONT PORCH LIGHT
3) REMOVE OR REWIRE ALL IMPROPERLY WIRED EXTERIOR LIGHTS
4) REMOVE EXTENSION CORDS THRU CEILING
5) REMOVE ARE THHN WIRE EXPOSED AT WATER HEATER
6) COVER BARE WIRES AT DOOR BELL TRANSFORMER
7) LIGHT FIXTURE AT CLOSET DAMAGED, REMOVE
8) PROVIDE OUTLET AND SWITCH COVERS
9) REMOVE POWER CORDS RUNNING THRU BEDROOM WALL
10) DO NOT RECALL INSPECTION UNTIL ALL ITEMS ON LIST HAVE BEEN COMPLETED, RETAIN QUALIFIED ELECTRICIAN TO COMPLETE WORK
12/14/2011 ELECTRIC - FINAL N/A Not ready for Inspection IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW