Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
600 N CITRUS AV
Address NEW:
600 N CITRUS AV
Apply Date:
09/15/2011
Applicant:
RUTH ROUBAL *APA*
Description:
RECONNECT: ELECTRIC: RES (APA)

Outstanding Activity Conditions

Permit Number - T11EL02452
Permit Status: Final
Permit Description: RECONNECT: ELECTRIC: RES (APA)
Total Outstanding Activity Conditions - 1
Date Name
09/15/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T11EL02452
Permit Description: RECONNECT: ELECTRIC: RES (APA)
Total Completed Inspections - 4
Date Description Inspector Results Comments
09/27/2011 ELECTRIC - FINAL DWALKER Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TO SECURE MAIN PANEL TO WALL
2) GROUNDING ELECTRODE CONDUCTOR NEEDS TO BE CONTINOUS, NO SPLICES ALLOWED AT MAIN OR SPLIT BOLTS
3) MAIN APPEARS TO E NEW-IS IT PERMITTED WITH CITY
4) NEED SMOKE DETECTORS IN ALL SLEEPING ROOMS AND HALL
5) NEED PROPER COVERS ON EXTERIOR RECEPTS/SWITCHES
09/27/2011 ELECTRIC - RECONNECT DWALKER Approved IVRS - Inspection :
See detailed listing on site.| 999*
03/08/2012 TEP CLEARANCE - AM JWEATHER Approved RECN CLEARED PER R. MORENO
03/08/2012 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW