Permit Details

Status:
Expired
Type:
SINGLE FAMILY COMPLIANCE
Address:
1942 S AMALIA AV
Address NEW:
1942 S AMALIA AV
Apply Date:
09/28/2011
Applicant:
KATIE CHOYGUHA
Description:
CODE COMPLIANCE FOR 2 AWNINGS, GARAGE AND ADD PATIO WALL 5'4" H X 207LF

Permit Reviews

Permit Number - T11CM03124
Permit Status: Expired
Permit Description: CODE COMPLIANCE FOR 2 AWNINGS, GARAGE AND ADD PATIO WALL 5'4" H X 207LF
Start Date Submittal Complete Date Status  
09/28/2011 RESIDENTIAL - BLDG/ZONING-WALKTHRU 09/28/2011 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T11CM03124
Permit Status: Expired
Permit Description: CODE COMPLIANCE FOR 2 AWNINGS, GARAGE AND ADD PATIO WALL 5'4" H X 207LF
Total Outstanding Activity Conditions - 1
Date Name
09/28/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T11CM03124
Permite Description: CODE COMPLIANCE FOR 2 AWNINGS, GARAGE AND ADD PATIO WALL 5'4" H X 207LF
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
09/29/2011 BUILDING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PATIO WALL WITHIN ESTABLISHED PROPERTY LINES PER SURVEYED PINS. NO INSPECTIONS REQUIRED FOR WALL UNDER 6' IN HEIGHT. MEETS ZONING REQUIREMENTS
2) FRONT AWNING NOT TO CODE. PROVIDE LEDGER TO BLDG PROPERLY ATTACHED EAST HEADER OVER SPANNED. SEE CROSS SECTION
3) OMIT HAZARDOUS ELECTRICAL FROM GARAGE CLIP TRUSS TO TOP PLATE CONNECTIONS. SECURE ALL SIDING 6" ON CENTER EDGES 12" IN FIELD FIRE RATE OVER HANGS WITHIN 36" OF PROPERTY LINE WITH 5/8" SHEETROCK OR WOOD SIDING
09/29/2011 ELECTRIC - FINAL N/A Denied IVRS - Inspection :