Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
08/25/2011
Applicant:
DAVE WINSOR
Description:
SFR PREF002011 T11-M0024
Contractors:
  • PREFERRED APARTMENT BUILDERS INC

Permit Reviews

Permit Number - T11CM02687
Permit Status: C of o
Permit Description: SFR PREF002011 T11-M0024
Start Date Submittal Complete Date Status  
08/26/2011 RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU 08/31/2011 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T11CM02687
Permit Status: C of o
Permit Description: SFR PREF002011 T11-M0024
Total Outstanding Activity Conditions - 1
Date Name
08/25/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T11CM02687
Permit Description: SFR PREF002011 T11-M0024
Total Completed Inspections - 27
Date Description Inspector Results Comments
10/07/2011 PLUMBING - YARD WTR LINE/TEST DQUINN Approved IVRS - Inspection :*
1) OK TOP BACKFILL
10/07/2011 PLUMBING - SEWER HCS CONNECT DQUINN Approved IVRS - Inspection :*
10/07/2011 PLUMBING - ROUGH, SOIL DQUINN Approved IVRS - Inspection :*
10/14/2011 ELECTRIC - UNDERGROUND DWALKER Approved IVRS - Inspection :*
10/14/2011 ELECTRIC - UFER DWALKER Approved IVRS - Inspection :*
10/14/2011 BUILDING PRE-SLAB DWALKER Approved IVRS - Inspection :*
10/14/2011 STEM WALL/RETAINING WALL DWALKER Approved IVRS - Inspection :*
10/14/2011 EXCAVATION/LAYOUT REBAR & ZON DWALKER Approved IVRS - Inspection :*
10/28/2011 ROOF NAILING DWALKER Approved IVRS - Inspection :*
10/28/2011 EXT METAL CLIPS/EXT SHEATHING DWALKER Approved IVRS - Inspection :*
11/09/2011 MECHANICAL - ABOVE CEILING DWALKER Approved IVRS - Inspection :*
11/09/2011 ELECTRIC - CONSTRUCTION POWER DWALKER Approved IVRS - Inspection :*
11/09/2011 ELECTRIC - CABLE DROP DWALKER Approved IVRS - Inspection :*
11/09/2011 FIREWALL/FIREBARRIER/FIRESTOP DWALKER Approved IVRS - Inspection :*
11/09/2011 U VALUE FOR WINDOW DWALKER Approved IVRS - Inspection :*
11/09/2011 STUCCO MESH DWALKER Approved IVRS - Inspection :*
11/09/2011 FRAMING DWALKER Approved IVRS - Inspection :*
11/09/2011 MECHANICAL - INTERMEDIATE DWALKER Approved IVRS - Inspection :*
11/09/2011 PLUMBING - INTERMEDIATE DWALKER Approved IVRS - Inspection :*
11/09/2011 ELECTRIC - INTERMEDIATE DWALKER Approved IVRS - Inspection :*
11/10/2011 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED FOR #1 PER D. WALKER
11/15/2011 SHEET ROCK NAILING DWALKER Approved IVRS - Inspection :*
01/18/2012 MECHANICAL - FINAL DWALKER Approved IVRS - Inspection :*
01/18/2012 PLUMBING - FINAL DWALKER Approved IVRS - Inspection :*
01/18/2012 ELECTRIC - FINAL DWALKER Approved IVRS - Inspection :*
01/18/2012 BUILDING - FINAL DWALKER Approved IVRS - Inspection :*
01/18/2012 OUTDOOR LIGHTING FINAL DWALKER Approved IVRS - Inspection :*

Documents

File Name Document Type  
C OF O_01-18-2012.TIF CERT OF OCC VIEW
None DOCUMENTS VIEW
001_C1.0.TIF CONSTRPLANS VIEW
002_C4.0.TIF CONSTRPLANS VIEW
003_C4.1.TIF CONSTRPLANS VIEW
004_C4.2.TIF CONSTRPLANS VIEW