Permit: T11CM02529
Permit Details
Status:
Closed
Type:
COMMERCIAL ADDITION
Address:
4101 E IRVINGTON RD
Address NEW:
4101 E IRVINGTON RD
Apply Date:
08/11/2011
Applicant:
N/A
Description:
FOUNDATION ONLY 5993 SF WEST ADDITION ONLY
Contractors:
- BARKER MORRISSEY CONTRACTING INC **C
Permit Reviews
Permit Number - T11CM02529
Permit Status: Closed
Permit Description: FOUNDATION ONLY 5993 SF WEST ADDITION ONLY
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/11/2011 | PLANS OK TO SUBMIT - COMM | 08/22/2011 | COMPLETED |
| 08/22/2011 | COMMERCIAL - BLDG/FIRE/ZONING/ENG | 09/19/2011 | COMPLETED |
| 08/24/2011 | SITE | 09/14/2011 | COMPLETED |
| 09/14/2011 | SITE | 09/21/2011 | COMPLETED |
| 09/26/2011 | RESUBMITTAL | 10/13/2011 | COMPLETED |
| 10/13/2011 | RESUBMITTAL | 10/13/2011 | COMPLETED |
| 10/13/2011 | REVISION - SITE | 10/18/2011 | COMPLETED |
| 10/13/2011 | RESUBMITTAL | 10/18/2011 | COMPLETED |
| 11/03/2011 | REVISION - SITE | 01/23/2012 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T11CM02529
Permit Status: Closed
Permit Description: FOUNDATION ONLY 5993 SF WEST ADDITION ONLY
Total Outstanding Activity Conditions - 12
| Date | Name |
|---|---|
| 08/11/2011 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 08/11/2011 | SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. |
| 08/11/2011 | SPECIAL INSPECTION FOR CONCRETE IS REQUIRED.. |
| 08/11/2011 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
| 09/16/2011 | SPECIAL INSPECTION FOR STRUCTURAL WELDING IS REQUIRED. |
| 08/11/2011 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
| 08/11/2011 | SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED. |
| 08/11/2011 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
| 08/11/2011 | SPECIAL INSPECTION FOR PILING, DRILLED PIERS AND CAISSONS IS REQUIRED. |
| 08/11/2011 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
| 08/11/2011 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
| 09/16/2011 | SPECIAL INSPECTION IS REQUIRED FOR HELICAL PIERS. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T11CM02529
Permite Description: FOUNDATION ONLY 5993 SF WEST ADDITION ONLY
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| BUILDING - PROGRESS | N/A | Not Inspected | ||
| BUILDING - FINAL | N/A | Not Inspected | ||
| FIRE SPKLR - FINAL | N/A | Not Inspected | ||
| FIRE - LANE SIGNS | N/A | Not Inspected | ||
| 12/02/2011 | EXCAVATION/LAYOUT REBAR & ZON | N/A | Partial Approval | IVRS - Inspection :* 1) GRADE BEAM AT GRID LINE A 3 TO 4 2) PATTERSON EVANOFF SPECIAL INSPECTED |
| 12/06/2011 | BUILDING PRE-SLAB | N/A | Partial Approval | IVRS - Inspection :* 1) WEST SLAB BETWEEN BLDGS |