Permit: T11CM01918
Permit Details
Apply Date:
06/20/2011
Applicant:
RUSSETT SOUTHWEST CORPORATION *APA*
Description:
REPLACE; 4 TON GAS PACK (APA)
Contractors:
- RUSSETT SOUTHWEST CORPORATION *APA*
Outstanding Activity Conditions
Permit Number - T11CM01918
Permit Status: Expired
Permit Description: REPLACE; 4 TON GAS PACK (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/20/2011 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T11CM01918
Permite Description: REPLACE; 4 TON GAS PACK (APA)
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/24/2011 | MECHANICAL - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 06/24/2011 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ALL PVC JOINTS TO BE PRIMERED PRIOR TO GLUE, PRIMER IS TO BE PURPLE IN COLOR PER UPC 2) ALL PVC EXPOSED TO DAY LIGHT IS TO BE COATED FOR U.V. PROTECTION 3) SERVICE DISCONNECT IS TO HAVE 36" CLEARANCE TO FACE 4) ELECTRICAL CONDUIT ON ROOF BROKEN 5) GAS PIPE ON ROOF NOT PROPERLY SUPPORTED 6) CONDENSATE TERMINATION AT GRADE IS TO BE 90 DEGREES AWAY FROM STRUCTURE |