Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Final
Type:
COMMERCIAL ALTERATION
Apply Date:
05/19/2011
Applicant:
WITMER, GALLAGHER
Description:
TI: SHELL
Architects:
  • WITMER, GALLAGHER
Contractors:
  • REPP CONSTRUCTION ,

Permit Reviews

Permit Number - T11CM01523
Permit Status: Final
Permit Description: TI: SHELL
Start Date Submittal Complete Date Status  
05/19/2011 COMMERCIAL - TI 05/20/2011 COMPLETED Review Details
06/08/2011 REVISION - - 1ST 06/08/2011 COMPLETED Review Details
06/08/2011 REVISION - - 1ST 06/08/2011 COMPLETED Review Details
06/10/2011 REVISION - - 2ND 06/13/2011 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T11CM01523
Permit Status: Final
Permit Description: TI: SHELL
Total Outstanding Activity Conditions - 1
Date Name
05/19/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T11CM01523
Permit Description: TI: SHELL
Total Completed Inspections - 11
Date Description Inspector Results Comments
06/09/2011 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
1) WATER TEST DWV FLOOR SINK AND HAND SINK THRU REVENT WITH AIR ADMITTANCE VALVE (2) LOCATIONS 1" HTCW LOOPED AS SHOWN. EXTENSION OF 4" BLDG DRAIN AS SHOWN
06/10/2011 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :*
1) PROVIDE VENT AT METER LOCATION, INSTALL WITH MINIMUM 6" ABOVE GRADE AND PROTECT FROM U.V.
06/16/2011 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
1) DELTA 2 REVISION MADE OK-OK TO COVER
06/20/2011 BUILDING - PROGRESS MHENSON Approved IVRS - Inspection :*
1) PRE-SLAB WRAP ALL PLUMBING
12/07/2011 NPPO - FINAL LHANLY Approved INTERIOR CHANGES TO PREVIOUSLY APPROVED SHELL SEE ACTIVITY T08CM01024
12/07/2011 SIGN - FINAL LHANLY Approved INTERIOR CHANGES TO PREVIOUSLY APPROVED SHELL SEE ACTIVITY T08CM01024
12/07/2011 LANDSCAPE - FINAL LHANLY Approved INTERIOR CHANGES TO PREVIOUSLY APPROVED SHELL SEE ACTIVITY T08CM01024
12/07/2011 ENGINEERING - FINAL LHANLY Approved INTERIOR CHANGES TO PREVIOUSLY APPROVED SHELL SEE ACTIVITY T08CM01024
03/08/2012 FIRE - FINAL DSIWARSKI Approved Shell Only
03/09/2012 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
03/09/2012 BUILDING - FINAL RMYERS Approved IVRS - Inspection :*