Permit: T11CM00726
Permit Details
Apply Date:
03/08/2011
Applicant:
N/A
Description:
REPLACE 2.5 TON ROOFTOP GAS PACK (APA)
Contractors:
- DESERT WEST COOLING AND HEATING,*C
Permit Reviews
Permit Number - T11CM00726
Permit Status: Expired
Permit Description: REPLACE 2.5 TON ROOFTOP GAS PACK (APA)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/08/2011 | OTHER | 03/16/2011 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T11CM00726
Permit Status: Expired
Permit Description: REPLACE 2.5 TON ROOFTOP GAS PACK (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/08/2011 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T11CM00726
Permite Description: REPLACE 2.5 TON ROOFTOP GAS PACK (APA)
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| MECHANICAL - INTERMEDIATE | N/A | Not Inspected | ||
| 03/31/2011 | MECHANICAL - FINAL | N/A | Partial Approval | IVRS - Inspection :* 1) THIS APPEARS TO BE A NEW INSTALLATION, PROVIDE CITY APPROVED TRUSS LOAD CALCS FOR ROOF TOP UNIT INSTALLATIONS 2) WHITE WIRE NOT TO BE USED AS A HOT LEG 3) CONDENSATE PIPING SUPPORT NO TO EXCEED 48" |