Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
01/21/2011
Applicant:
N/A
Description:
SFR:CORN215010 T10-M0049
Contractors:
  • CORNERSTONE HOMES LLC

Permit Reviews

Permit Number - T11CM00179
Permit Status: C of o
Permit Description: SFR:CORN215010 T10-M0049
Start Date Submittal Complete Date Status  
01/21/2011 RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU 01/25/2011 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T11CM00179
Permit Status: C of o
Permit Description: SFR:CORN215010 T10-M0049
Total Outstanding Activity Conditions - 1
Date Name
01/21/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T11CM00179
Permit Description: SFR:CORN215010 T10-M0049
Total Completed Inspections - 26
Date Description Inspector Results Comments
01/31/2011 PLUMBING - SEWER HCS CONNECT DQUINN Approved IVRS - Inspection :*
01/31/2011 PLUMBING - YARD WTR LINE/TEST DQUINN Approved IVRS - Inspection :*
01/31/2011 PLUMBING - ROUGH, SOIL DQUINN Approved IVRS - Inspection :*
02/03/2011 BUILDING PRE-SLAB DQUINN Approved IVRS - Inspection :*
02/03/2011 EXCAVATION/LAYOUT REBAR & ZON DQUINN Approved IVRS - Inspection :*
02/23/2011 EXT METAL CLIPS/EXT SHEATHING DWALKER Approved IVRS - Inspection :*
1) MISSING AB'S AT COLUMNS (DETAIL 310)
02/23/2011 ROOF NAILING DWALKER Approved IVRS - Inspection :*
03/02/2011 ELECTRIC - CABLE DROP DQUINN Approved IVRS - Inspection :*
03/03/2011 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER D. QUINN
03/09/2011 PLUMBING - GAS PRESSURE TEST DQUINN Approved
03/09/2011 FRAMING DQUINN Approved IVRS - Inspection :*
03/09/2011 MECHANICAL - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
03/09/2011 PLUMBING - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
03/09/2011 ELECTRIC - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
03/09/2011 ELECTRIC - UNDERGROUND DQUINN Approved IVRS - Inspection :*
03/09/2011 ELECTRIC - UFER DQUINN Approved IVRS - Inspection :*
03/09/2011 U VALUE FOR WINDOW DQUINN Approved IVRS - Inspection :*
03/09/2011 STUCCO MESH DQUINN Approved IVRS - Inspection :*
03/21/2011 SHEET ROCK NAILING DWALKER Approved IVRS - Inspection :*
06/06/2011 MECHANICAL - FINAL DWALKER Approved IVRS - Inspection :*
06/06/2011 PLUMBING - FINAL DWALKER Approved IVRS - Inspection :*
06/06/2011 ELECTRIC - FINAL DWALKER Approved IVRS - Inspection :*
06/06/2011 BUILDING - FINAL DWALKER Approved IVRS - Inspection :*
06/06/2011 BUILDING - PROGRESS DWALKER Approved IVRS - Inspection :*
06/06/2011 ELECTRIC - OUTDOOR LIGHTING DWALKER Approved IVRS - Inspection :*
06/06/2011 OUTDOOR LIGHTING FINAL DWALKER Approved IVRS - Inspection :*

Documents

File Name Document Type  
C OF O_06-06-2011.TIF CERT OF OCC VIEW
None CONSTRPLANS VIEW
None DOCUMENTS VIEW