Permit: T11BU01539
Permit Details
Apply Date:
11/18/2011
Applicant:
ANA SANTIAGO
Description:
RAMADA AND STORAGE- RES
Permit Reviews
Permit Number - T11BU01539
Permit Status: Final
Permit Description: RAMADA AND STORAGE- RES
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/18/2011 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 11/22/2011 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T11BU01539
Permit Status: Final
Permit Description: RAMADA AND STORAGE- RES
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/18/2011 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T11BU01539
Permit Description: RAMADA AND STORAGE- RES
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/30/2011 | BUILDING - FINAL | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) EXPOSE FOOTERS TO VERIFY DEPTH BOTH STRUCTURES 2) INSTALL LU26 AT RIDGE BEAM REAR PORCH 3) INSTALL BEAM AT GABLE TO REINFORCE RIDGE BEAM AT GABLE END BLOCK RIDGE BEAM TO CODE 4) EXPOSE ROOF STRUCTURE FOR INSPECTION AT STORAGE 5) POST MAY NOT BE EMBEDDED IN CONCRETE AT RAMADA. PROVIDE POST BASE 6) SITE PLAN SHOWS 5' SET BACK 3' X 3' SET BACK SUBMIT AS BUILT |
| 11/30/2011 | BUILDING - PROGRESS | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |