Permit: T11BU00018
Permit Details
Apply Date:
01/06/2011
Applicant:
PETER ABRAHAM
Description:
GRADING FOR NEW WELL SITE
Permit Reviews
Permit Number - T11BU00018
Permit Status: Withdrwn
Permit Description: GRADING FOR NEW WELL SITE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/06/2011 | PLANS OK TO SUBMIT - GRADING | 01/06/2011 | COMPLETED |
| 01/06/2011 | GRADING | 02/04/2011 | COMPLETED |
| 02/04/2011 | RESUBMITTAL - GRADING | 02/04/2011 | ACTIVE |
Outstanding Activity Conditions
Permit Number - T11BU00018
Permit Status: Withdrwn
Permit Description: GRADING FOR NEW WELL SITE
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 01/06/2011 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 02/04/2011 | 1) The following conditions apply to grading permit T11BU00018: a) This permit is for the initial phase of the Tucson Water SAVSARP well improvements SA-001A phase 1 only. b) The Southern Avra Valley Storage And Recovery Project (SAVSARP) Well SA-001A Phase 1 plans - Tucson Water Plan No.1-027-2010 (SA-001A) and specifications are a part of the grading permit. See also Floodplain Analysis Summary Report for Southern Avra Valley Storage and Recovery Project (SAVSARP) Planned Recovery-Well Pad Sites by TetraTech dated December 9, 2009, sealed 12/09/09 Michael Zeller, P.E. c) Minimum pad elevation and well structure shall be set above the jurisdictional water surface to the elevation, as shown on the approved plans and drainage report, and shall be certified by an RLS. |
| 02/04/2011 | d) Submit completed elevation certificates to City of Tucson Planning & Development Services Department Engineering Division for acceptance. For SAVSARP Well SA-001A, submit first elevation certificate after compaction and completion of the fill pad, and final elevation certificate indicating minimum elevation of base flange of well casing. The Floodplain Analysis Summary Report states that the upstream WSEL is 2296.52 and interpolated depth of flood at the well cover of 1.38, and that the well casing shall be 2-ft above this flood level. Elevation certificates are required to show minimum pad grade of 2302.81, and well casing base flange at minimum 2304.81 (using existing grade at well casing 2301.43). e) Submit a copy of the as-builts to City of Tucson Planning & Development Services Department upon completion. 2) All conditions of Pima County Regional Flood Control District Floodplain Use Permit No.10-010 approved 2/16/10 shall apply. 3) Additional grading and floodplain review by the City of Tucson Planning & Development Services Department will be required for permits for the future structures or other future phase improvements on the constructed pad. At the time when permits are required for the future control building, submit copy of final elevation certificate with plans and drainage statement. |
Outstanding Inspections
Permit Status: Withdrwn
Permit Number: T11BU00018
Permite Description: GRADING FOR NEW WELL SITE
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| GRADING - TIER REV | N/A | Not Inspected |