Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T10PL01498
Permit Details
Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
2513 N CASTRO AV #A
Address NEW:
2513 N CASTRO AV #A
Apply Date:
09/28/2010
Applicant:
RANDY ORR
Description:
REPLACE WATER HEATER; T10DV05532
Permit Reviews
Permit Number - T10PL01498
Permit Status: Final
Permit Description: REPLACE WATER HEATER; T10DV05532
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/28/2010 | PLUMBING | 09/28/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10PL01498
Permit Status: Final
Permit Description: REPLACE WATER HEATER; T10DV05532
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/28/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T10PL01498
Permit Description: REPLACE WATER HEATER; T10DV05532
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/18/2010 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1) UNIT B-WATER HEATER FLEX UNDERSIZED AND TO LONG 2) REQUIRE SHUT OFF AT COLD INLET 3) T & P RELIEF DRAIN TO BE APPROVED TYPE NO THREADS ON THE END 4) VENT TO BE "B" VENT UNIT A: 1) INSTALL SHUT OFF VALVE AGA OR CSA APPROVED 2) SHUT OFF COLD INLET |
| 04/12/2011 | PERMIT FINALED | JWEATHER | Approved |