Permit: T10PL01293
Permit Details
Apply Date:
08/16/2010
Applicant:
QUINN KRISTI
Description:
PER INSPECTOR NEED TO ORDER WATER REPIPE INSPECTION PERMIT FOR SOLAR TUBING
Contractors:
- RUSSET SERVICE CORPORATION *APA*
Outstanding Activity Conditions
Permit Number - T10PL01293
Permit Status: Final
Permit Description: PER INSPECTOR NEED TO ORDER
WATER REPIPE INSPECTION PERMIT
FOR SOLAR TUBING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/16/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T10PL01293
Permit Description: PER INSPECTOR NEED TO ORDER
WATER REPIPE INSPECTION PERMIT
FOR SOLAR TUBING
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2010 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* 1) PROVIDE VACUUM BREAKER ON ALL HOSE BIBS 2) THE REPAIR COUPLING ON THE SERVICE ENTRY HAS NEGATED THE BLDG ELECTRICAL GROUNDING ELECTRODE. PROVIDE ELECTRICAL GROUNDING PER 2006 NEC. PROVIDE MINIMUM 2 GROUND RODS 6' APART WITH CONTINOUS GROUND WIRE FROM PANEL WITH CORRECT GROUND ROD CLAMPS |
| 08/18/2010 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* |