Description:
Replace gas heat split system, 5 ton 16 seer 80%afue. Like for like.
Contractors:
  • RITEWAY VENTILATING *C*

Outstanding Activity Conditions

Permit Number - T10ME00516
Permit Status: Expired
Permit Description: Replace gas heat split system, 5 ton 16 seer 80%afue. Like for like.
Total Outstanding Activity Conditions - 1
Date Name
08/11/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T10ME00516
Permite Description: Replace gas heat split system, 5 ton 16 seer 80%afue. Like for like.
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
08/26/2010 MECHANICAL - FINAL N/A Partial Approval IVRS - Inspection :*
1) TERMINATE COPPER CONDENSATE DRAIN WITH A FITTING
2) PROVIDE DBL WALL VENT PIPE FROM FURNACE ROOM THRU ROOF WITH AN APPROVED CAP
3) FURNACE VENT CONNECTOR TO TERMINATE INTO BOTTOM OF TEE AND WATER HEATER INTO SIDE OF TEE
4) COMBUSTION AIR SCREEN NEEDS TO BE FITTED AROUND REFER LINES

Completed Inspections

Permit Status: Expired
Permit Number: T10ME00516
Permit Description: Replace gas heat split system, 5 ton 16 seer 80%afue. Like for like.
Total Completed Inspections - 1
Date Description Inspector Results Comments
08/26/2010 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*