Permit: T10ME00502
Permit Details
Apply Date:
08/05/2010
Applicant:
AMERICAN HOME MAINTENANCE INC *C*
Description:
REPLACE; 4 TON GROUND MOUNT SPLIT SYSTEM (APA)
Contractors:
- AMERICAN HOME MAINTENANCE INC *C*
Outstanding Activity Conditions
Permit Number - T10ME00502
Permit Status: Final
Permit Description: REPLACE; 4 TON GROUND MOUNT SPLIT SYSTEM (APA)
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/05/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T10ME00502
Permit Description: REPLACE; 4 TON GROUND MOUNT SPLIT SYSTEM (APA)
Total Completed Inspections - 3
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/14/2010 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) DO NOT USE A DBL WALL INCREASER ON THE FURNACE OUTLET. USE SINGLE WALL 2) ALL CRIMPED ENDS OF VENT CONNECTOR TO GO SAME DIRECTION AS AIR FLOW 3) PROVIDE A BUSHING IN ELECTRIC DISCONNECT TO PROTECT CONDUCTORS ENTERING DISCONNECT 4) PROVIDE A PROTECTIVE COATING ON EXPOSED ARMAFLEX |
03/15/2011 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
03/28/2011 | PERMIT FINALED | JWEATHER | Approved |