Permit: T10ME00263
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
1666 S AVENIDA URSA
Address NEW:
1666 S AVENIDA URSA
Apply Date:
05/07/2010
Applicant:
AMERICAN HOME MAINTENANCE INC *C*
Description:
REPLACE: 3 TON ROOF TOP GAS PACK (APA)
Contractors:
- AMERICAN HOME MAINTENANCE INC *C*
Outstanding Activity Conditions
Permit Number - T10ME00263
Permit Status: Expired
Permit Description: REPLACE: 3 TON ROOF TOP GAS PACK (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/07/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T10ME00263
Permite Description: REPLACE: 3 TON ROOF TOP GAS PACK (APA)
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| MECHANICAL - INTERMEDIATE | N/A | Not Inspected | ||
| 09/21/2010 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TERMINATE CONDENSATE TO WITHIN 6" OF THE GROUND 2) PROVIDE A PERMIT FOR NEW SERVICE UPGRADE 3) DO NOT USE 3 WHITE CONDUCTOR FOR POWER, GROUND AND NEUTRAL TO THE SERVICE RECEPT. A/C UNIT IS OVERFUSED 4) PROVIDE MINIMUM 2" R8 DUCT LINER IN EXPOSED DUCT ON ROOF |