Permit: T10ME00234
Permit Details
Apply Date:
04/26/2010
Applicant:
VINEYARD HOMES L L C
Description:
REPLACE:FURANCE
Contractors:
- VINEYARD HOMES L L C
Permit Reviews
Permit Number - T10ME00234
Permit Status: Final
Permit Description: REPLACE:FURANCE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/26/2010 | MECHANICAL | 04/26/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10ME00234
Permit Status: Final
Permit Description: REPLACE:FURANCE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/26/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T10ME00234
Permit Description: REPLACE:FURANCE
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/08/2010 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) VENT CONNECTORS CANNOT BE REDUCED 2) REMOVE ALL FOIL TAPE FROM VENTS AND PROVIDE MINIMUM 3 SCREWS IN ALL JOINTS 3) PROVIDE AN OVERFLOW SENSOR ON SECONDARY DRAIN 4) PROVIDE A ROMEX CONNECTOR FOR FURNACE CORD 5) LOW VOLTAGE WIRE MUST BE PROTECTED 6) DO NOT USE WHITE WIRE FOR A/C POWER 7) SUPPORT ELECTRIC CONDUIT ON ROOF AND PROVIDE ROOF JACKS |