Permit: T10ME00213
Permit Details
Status:
Closed
Type:
SINGLE FAMILY OTHER
Address:
7811 E CLARENCE PL
Address NEW:
7811 E CLARENCE PL
Apply Date:
04/15/2010
Applicant:
AMERICAN HOME MAINTENANCE INC *C*
Description:
REPLACE HEATER W/ 5 TON ROOFTOP GAS PACK (APA) T10DV01637
Contractors:
- AMERICAN HOME MAINTENANCE INC *C*
Permit Reviews
Permit Number - T10ME00213
Permit Status: Closed
Permit Description: REPLACE HEATER W/ 5 TON ROOFTOP GAS PACK (APA) T10DV01637
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/17/2010 | MECHANICAL | 06/17/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10ME00213
Permit Status: Closed
Permit Description: REPLACE HEATER W/ 5 TON ROOFTOP GAS PACK (APA) T10DV01637
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/15/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T10ME00213
Permite Description: REPLACE HEATER W/ 5 TON ROOFTOP GAS PACK (APA) T10DV01637
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/20/2010 | ELECTRIC - FINAL | N/A | Partial Approval | IVRS - Inspection :* 1) ID CIRCUIT BREAKER FOR A/C UNIT 2) RELOCATE ELECTRIC CONDUIT FROM TOP OF PANEL BLOCKING PANEL DOOR FROM OPENING 3) ELECTRIC DISCONNECT CANNOT BE MOUNTED TO A SERVICE ACCESS PANEL |
Completed Inspections
Permit Status: Closed
Permit Number: T10ME00213
Permit Description: REPLACE HEATER W/ 5 TON ROOFTOP GAS PACK (APA) T10DV01637
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/20/2010 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) AIR BLOWING THRU RETURN GRILLE BAROMETRIC DAMPERS MUST BE ACCESSIBLE 2) REMOVE THE EXTERNAL CONDENSATE DRAIN TRAP. UNIT ALL READY HAS ONE BUILT IN 3) PROVIDE A PROTECTIVE COATING ON EXPOSED ARMAFLEX USED FOR GAS LINE |
| 10/20/2010 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
| 10/20/2010 | PLUMBING - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 10/20/2010 | PLUMBING - GAS PRESSURE TEST | JMILITEL | Approved | IVRS - Inspection :* |