Permit: T10EL00046
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
5515 E BELLEVUE ST
Address NEW:
5515 E BELLEVUE ST
Apply Date:
01/11/2010
Applicant:
BROKEN ARROW ELECTRIC L L C
Description:
UPGRADE: ELECTRIC FROM 60-200 AMPS (APA)
Contractors:
- BROKEN ARROW ELECTRIC L L C
Outstanding Activity Conditions
Permit Number - T10EL00046
Permit Status: Expired
Permit Description: UPGRADE: ELECTRIC FROM 60-200 AMPS (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/11/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T10EL00046
Permite Description: UPGRADE: ELECTRIC FROM 60-200 AMPS (APA)
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/14/2010 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO BRACE RISER 2) NEED TO STRAP GROUNDING ELECTRODE CONDUCTOR AROUND PANEL 3) NEED TO USE 2/0 CU. FOR 200 AMP SERVICE 4) NEED TO BOND GAS AND WATER 5) NEED POWER KILL AND INSPECTION BEFORE RECONNECT 6) NEED TO TIGHTEN UP 1" EMT AND STRAP IT ON RIGHT SIDE OF PANEL |
Completed Inspections
Permit Status: Expired
Permit Number: T10EL00046
Permit Description: UPGRADE: ELECTRIC FROM 60-200 AMPS (APA)
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/19/2010 | ELECTRIC - SERVICE UPGRADE | RMORENO | Approved | ITEMS ON LIST OK |
| 01/20/2010 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER R. MORENO |