Description:
REPLACE EXISTING SOLAR HOT WATER HEATER & REPLACE GAS HOT WH
Contractors:
  • AUTHENTIC CONSTRUCTION GROUP INC

Permit Reviews

Permit Number - T10CM03378
Permit Status: Expired
Permit Description: REPLACE EXISTING SOLAR HOT WATER HEATER & REPLACE GAS HOT WH
Start Date Submittal Complete Date Status  
02/16/2011 REVISION - - 1ST 02/16/2011 COMPLETED Review Details
12/03/2010 RESIDENTIAL - BLDG/ZONING-WALKTHRU 12/07/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM03378
Permit Status: Expired
Permit Description: REPLACE EXISTING SOLAR HOT WATER HEATER & REPLACE GAS HOT WH
Total Outstanding Activity Conditions - 1
Date Name
12/03/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T10CM03378
Permite Description: REPLACE EXISTING SOLAR HOT WATER HEATER & REPLACE GAS HOT WH
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
02/24/2011 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) THE CLAMPS AROUND THE PIPE INSULATION ARE NOT SUPPORTING THE PIPING OR COMPONENTS
2) PLUMBER TAPE IS NOT APPROVED AND IS CUTTING INTO PIPE INSULATION
3) PROVIDE APPROVED PIPING CLAMPS AND SUPPORT PROPERLY
4) GFI OR DEDICATED OUTLET FOR PUMP REQUIRED
5) EXPOSED ROMEX IS NOT ACCEPTABLE
12/27/2010 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
1) PROVIDE APPROVED PLAN FOR SOLAR AND GAS
2) EXTEND B-VENT
3) REPLACE GAS FLEX, INSTALL SEDIMENT TRAP SUPPORT/SECURE ALL PIPING WITH ACCESS TO ALL COMPONENTS

Completed Inspections

Permit Status: Expired
Permit Number: T10CM03378
Permit Description: REPLACE EXISTING SOLAR HOT WATER HEATER & REPLACE GAS HOT WH
Total Completed Inspections - 1
Date Description Inspector Results Comments
12/27/2010 BUILDING - FINAL BBENEDON Approved IVRS - Inspection :*