Permit: T10CM03235
Permit Details
Apply Date:
11/16/2010
Applicant:
N/A
Description:
COMPLIANCE; PORCH, RAMADA & DETACHED STORAGED SHED; T10DV02089
Permit Reviews
Permit Number - T10CM03235
Permit Status: Final
Permit Description: COMPLIANCE; PORCH, RAMADA & DETACHED STORAGED SHED; T10DV02089
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/16/2010 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 12/01/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10CM03235
Permit Status: Final
Permit Description: COMPLIANCE; PORCH, RAMADA & DETACHED STORAGED SHED; T10DV02089
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/16/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T10CM03235
Permit Description: COMPLIANCE; PORCH, RAMADA & DETACHED STORAGED SHED; T10DV02089
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2010 | BUILDING - FINAL | WLAHR | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/23/2010 | BUILDING - PROGRESS | DQUINN | Approved | IVRS - Inspection :* 1) FIRE RATE EAST GABLE WALL OF SHED 2) PORCH BEAMS AND RAFTERS MUST BE UP-SIZED 3) CORRECT BEAM/RAFTER CONSTRUCTION AT S.W. CORNER OF PORCH OR REMOVE 4) STRAP RAMADA BEAMS AND ADD COLLAR TIES-1 IN EACH DIRECTION 5) FIRE RATE WINDOWS IN GARAGE SOUTH WALL 6) ALL OTHER ITEMS OF DEFICIENCIES ON 12/22/ ARE OK |