Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T10CM02624
Permit Details
Apply Date:
09/20/2010
Applicant:
N/A
Description:
SOLAR WATER HEATER
Contractors:
- ADAIR PLUMBING L L C
Permit Reviews
Permit Number - T10CM02624
Permit Status: Final
Permit Description: SOLAR WATER HEATER
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/20/2010 | PLANS OK TO SUBMIT - RES | 09/24/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10CM02624
Permit Status: Final
Permit Description: SOLAR WATER HEATER
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
09/20/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T10CM02624
Permit Description: SOLAR WATER HEATER
Total Completed Inspections - 3
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/06/2010 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* 1) PROVIDE PROTECTION FROM VEHICLE COLLISION FOR WATER HEATER AND STORAGE TANK PER APPROVED PLANS 2) PROVIDE 6" MINIMUM CLEARANCE FROM COMBUSTIBLES AND VENT CONNECTOR OF WATER HEATER 3) PROVIDE FLASHING FOR THRU ROOF PIPING PENETRATIONS AT TILE 4) PROVIDE ACCESS TO ATTIC SPACE 5) PANEL SUPPORT NOT DECKING AND PROPERLY FLASHED 6) OUTLET FOR PUMP TO BE GFI PROTECTED 7) LIST NOT COMPLETE |
10/06/2010 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* |
03/21/2011 | PERMIT FINALED | JWEATHER | Approved |