Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address NEW:
9630 E 22ND ST #100
Apply Date:
09/07/2010
Applicant:
N/A
Description:
TI: MASSAGE OFFICE " MASSAGE ENVY"
Architects:
  • RAWSON, RHONDA LEE
Contractors:
  • COFFEE CONSTRUCTION INC

Permit Reviews

Permit Number - T10CM02476
Permit Status: C of o
Permit Description: TI: MASSAGE OFFICE " MASSAGE ENVY"
Start Date Submittal Complete Date Status  
09/07/2010 COMMERCIAL TI 09/08/2010 COMPLETED Review Details
09/08/2010 OTHER 12/10/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM02476
Permit Status: C of o
Permit Description: TI: MASSAGE OFFICE " MASSAGE ENVY"
Total Outstanding Activity Conditions - 1
Date Name
09/07/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T10CM02476
Permit Description: TI: MASSAGE OFFICE " MASSAGE ENVY"
Total Completed Inspections - 31
Date Description Inspector Results Comments
10/06/2010 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
1) WATER TEST OK
10/06/2010 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED FOR #100 PER R. JIROUDEK
10/13/2010 ELECTRIC - UNDERGROUND RJIROUDE Approved IVRS - Inspection :*
10/13/2010 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
11/05/2010 FRAMING JBURGE Approved IVRS - Inspection :*
1) OK TO SHEETROCK
11/05/2010 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
11/24/2010 TEP CLEARANCE - PM JWEATHER Approved TEC CLEARED FOR #100 PER L. HANLY
11/30/2010 PLUMBING - GAS PRESS TEST FNL RRICH Approved IVRS - Inspection :*
11/30/2010 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :*
11/30/2010 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
11/30/2010 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection :*
12/01/2010 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
1) PROVIDE BEADED COLLARS ON ALL CEILING DIFFUSERS-WILL CHECK AT FINAL
2) ROOM 3 MISSING RETURN AIR-WILL CHECK AT FINAL
3) CONDENSATE PIPING OK
12/01/2010 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
12/03/2010 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
1) OK TO SET CEILING TILES
12/03/2010 FIRE SPKLR - FINAL DSIWARSKI Approved
12/03/2010 BUILDING - PROGRESS JBURGE Approved IVRS - Inspection :*
12/03/2010 NPPO - FINAL JFEMLING Approved Approved
12/03/2010 LANDSCAPE - FINAL JFEMLING Approved Approved
12/03/2010 ENGINEERING - FINAL JFEMLING Approved Approved
12/03/2010 RIGHT OF WAY - FINAL P.Whiddon Approved
12/06/2010 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
12/06/2010 ELECTRIC - RECONNECT RJIROUDE Approved IVRS - Inspection :*
12/06/2010 ELECTRIC - ABOVE CEILING RJIROUDE Approved IVRS - Inspection :*
12/06/2010 FIRE - FINAL LTHOMAS Approved
12/08/2010 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
1) INSTALL CLIPS ON FRONT SIDE OF SINK
2) CORRECT LEAK ON MV'S
3) BACTERIA REPORT
12/08/2010 MECHANICAL - FINAL RJIROUDE Approved IVRS - Inspection :*
1) SAW AIR BALANCE REPORT
12/08/2010 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
12/08/2010 SHEET ROCK NAILING LHANLY Approved
12/09/2010 BUILDING - FINAL GDABBS Approved IVRS - Inspection :*
12/09/2010 CERTIFICATE OF OCCUPANCY GDABBS Approved IVRS - Inspection :*
12/10/2010 SIGN - FINAL LHANLY Approved

Documents

File Name Document Type  
C OF O_12-10-2010.TIF CERT OF OCC VIEW
C OF O_01-24-2011.TIF CERT OF OCC VIEW
001_CVR.TIF CONSTRPLANS VIEW
002_A1.TIF CONSTRPLANS VIEW
003_A2.TIF CONSTRPLANS VIEW
004_A3.TIF CONSTRPLANS VIEW
005_P1.TIF CONSTRPLANS VIEW
006_P2.TIF CONSTRPLANS VIEW
007_M1.TIF CONSTRPLANS VIEW
008_E1.TIF CONSTRPLANS VIEW
009_E2.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW