Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY COMPLIANCE
Address NEW:
6740 S MISSIONDALE RD
Apply Date:
07/06/2010
Applicant:
N/A
Description:
CODE COMPLIANCE:CARPORT TO ROOM:ADD:GARAGE & PORCH T09CM00280

Outstanding Activity Conditions

Permit Number - T10CM01851
Permit Status: Final
Permit Description: CODE COMPLIANCE:CARPORT TO ROOM:ADD:GARAGE & PORCH T09CM00280
Total Outstanding Activity Conditions - 1
Date Name
07/06/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T10CM01851
Permit Description: CODE COMPLIANCE:CARPORT TO ROOM:ADD:GARAGE & PORCH T09CM00280
Total Completed Inspections - 17
Date Description Inspector Results Comments
08/20/2010 BUILDING - FINAL RMAJUTA Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) SERVICE INCREASE MUST HAVE A LEVEL SURFACE IN FRONT
2) TRANSFER ALL CIRCUITRY FROM OLD SERVICE TO NEW SERVICE
3) DRIVE GROUND RODS FLUSH TO GRADE AND BURY GROUND WIRE
4) NEED WATER BOND
5) SEAL OPENING THRU ROOF FOR 2" CONDUIT
6) INSTALL SUB PANEL AND TIE THE CIRCUITS
7) TO MANY ITEMS ON PLANS NOT COMPLETED, PLANS MUST BE FOLLOWED-SEE REQUIREMENTS
08/23/2010 ELECTRIC - TEMPORARY SERVICE RCAMACHO Approved IVRS - Inspection :*
08/23/2010 ELECTRIC - SERVICE RELOCATION RCAMACHO Approved IVRS - Inspection :*
08/23/2010 U VALUE FOR WINDOW RCAMACHO Approved IVRS - Inspection :*
08/24/2010 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED PER R. CAMACHO
09/07/2010 SHEET ROCK NAILING RCAMACHO Approved IVRS - Inspection :*
10/22/2010 BUILDING PRE-SLAB RCAMACHO Approved
10/22/2010 EXCAVATION/LAYOUT REBAR & ZON RCAMACHO Approved
11/24/2010 ROOF NAILING RCAMACHO Approved IVRS - Inspection :*
11/29/2010 FRAMING RCAMACHO Approved IVRS - Inspection :*
1) CANCELLED
11/29/2010 PLUMBING - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :*
11/29/2010 ELECTRIC - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :*
11/29/2010 STUCCO MESH RCAMACHO Approved IVRS - Inspection :*
06/14/2011 MECHANICAL - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :*
03/06/2012 MECHANICAL - FINAL DQUINN Approved IVRS - Inspection :*
03/06/2012 PLUMBING - FINAL DQUINN Approved IVRS - Inspection :*
03/06/2012 ELECTRIC - FINAL DQUINN Approved IVRS - Inspection :*

Documents

File Name Document Type  
001_PLOT PLAN .TIF CONSTRPLANS VIEW
002_FOUND PLAN.TIF CONSTRPLANS VIEW
003_FLOOR PLAN.TIF CONSTRPLANS VIEW
004_ROOF FRAMING PLAN.TIF CONSTRPLANS VIEW
005_ELEVATIONS.TIF CONSTRPLANS VIEW
006_SECTION AA.TIF CONSTRPLANS VIEW
007_MECH & ELEC.TIF CONSTRPLANS VIEW
007_PLUMB & MECH PLAN.TIF CONSTRPLANS VIEW
008_ELECT PLAN.TIF .TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW
None DOCUMENTS VIEW