Permit: T10CM01310
Permit Details
Apply Date:
05/13/2010
Applicant:
N/A
Description:
NEW 1TON MINI SPLIT SYSTEM
Contractors:
- CUMMINGS PLUMBING INC , *C
Permit Reviews
Permit Number - T10CM01310
Permit Status: Expired
Permit Description: NEW 1TON MINI SPLIT SYSTEM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/13/2010 | OTHER | 05/13/2010 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T10CM01310
Permit Status: Expired
Permit Description: NEW 1TON MINI SPLIT SYSTEM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/13/2010 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T10CM01310
Permite Description: NEW 1TON MINI SPLIT SYSTEM
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/14/2010 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OK TO ELIMINATE LOWER COMBSUTION AIR OPENING AND USE THE ONE OPENING METHOD ALLOWED BY CODE FOR WATER HEATER 2) UPPER OPENING MUST BE MIN. 1 SQ. INCH PER 3,000 BTU 3) TERMINATE CONDENSATE TO WITHIN 6" OF THE GROUND WITH AN ELBOW AND NIPPLE 4) PROVIDE A PERMIT FOR NEW FURNACE AND CONDENSOR 5) NEEDS AN OVERFLOW SENSOR 6) CONDENSOR OVERFUSED |
| 05/14/2010 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |