Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Apply Date:
03/26/2010
Applicant:
N/A
Description:
ADDITION: ENLARGE BEDROOM & DINING ROOM, REMODEL KITCHEN
Contractors:
  • GERARD AND COMPANY INC

Permit Reviews

Permit Number - T10CM00772
Permit Status: Final
Permit Description: ADDITION: ENLARGE BEDROOM & DINING ROOM, REMODEL KITCHEN
Start Date Submittal Complete Date Status  
03/26/2010 RESIDENTIAL BLDG/ZONING/ENGINE/WWM 04/01/2010 COMPLETED Review Details
04/12/2010 REVISION - - 1ST 04/12/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T10CM00772
Permit Status: Final
Permit Description: ADDITION: ENLARGE BEDROOM & DINING ROOM, REMODEL KITCHEN
Total Outstanding Activity Conditions - 1
Date Name
03/26/2010 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T10CM00772
Permit Description: ADDITION: ENLARGE BEDROOM & DINING ROOM, REMODEL KITCHEN
Total Completed Inspections - 22
Date Description Inspector Results Comments
04/13/2010 PLUMBING - SEWER HCS CONNECT DQUINN Approved IVRS - Inspection :*
1) NEW 4" TO CLAY AT S.E. CORNER OF NEW ADDITION AND ALL EXTERIOR ABS TO N.E. CORNER OF NEW ADDITION OK TO BACKFILL
04/14/2010 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection :*
04/14/2010 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved IVRS - Inspection :*
04/14/2010 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection :*
04/14/2010 ELECTRIC - SERVICE RELOCATION RFREIDIN Approved IVRS - Inspection :*
04/15/2010 TEP CLEARANCE - AM JWEATHER Approved ECO/RELOCATION CLEARED FOR #1 PER R. FREIDINGER
04/20/2010 ROOF NAILING GDABBS Approved IVRS - Inspection :*
04/20/2010 EXT METAL CLIPS/EXT SHEATHING GDABBS Approved IVRS - Inspection :*
04/27/2010 PLUMBING - GAS PRESSURE TEST DQUINN Approved IVRS - Inspection :*
04/27/2010 FRAMING DQUINN Approved IVRS - Inspection :*
04/27/2010 MECHANICAL - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
04/27/2010 PLUMBING - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
04/27/2010 ELECTRIC - INTERMEDIATE DQUINN Approved IVRS - Inspection :*
04/27/2010 U VALUE FOR WINDOW DQUINN Approved IVRS - Inspection :*
05/05/2010 SHEET ROCK NAILING GDABBS Approved IVRS - Inspection :*
05/05/2010 STUCCO MESH GDABBS Approved IVRS - Inspection :*
06/03/2010 MECHANICAL - FINAL DQUINN Approved IVRS - Inspection :*
06/03/2010 PLUMBING - FINAL DQUINN Approved IVRS - Inspection :*
06/03/2010 ELECTRIC - FINAL DQUINN Approved IVRS - Inspection :*
06/03/2010 BUILDING - FINAL DQUINN Approved IVRS - Inspection :*
06/03/2010 PLUMBING - GAS PRESS TEST FNL DQUINN Approved IVRS - Inspection :*
06/10/2010 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
001_PLOT PLAN.TIF CONSTRPLANS VIEW
002_REMODEL PLAN.TIF CONSTRPLANS VIEW
003_FOUND & ELEVATION.TIF CONSTRPLANS VIEW
004_ELEC PLAN.TIF CONSTRPLANS VIEW
005_PLUMBING PLAN.TIF CONSTRPLANS VIEW
006_MECH PLAN.TIF CONSTRPLANS VIEW
007_RAFTER PLAN.TIF CONSTRPLANS VIEW
008_NOTES.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW